B4.2 Install & Operation Manual
Borg & Overström
AU
14
Leak Detection (power cut off) - All Variants
Enhanced Leak Detection (Flood prevention) Available as Optional Extra.
NOTE:
If this machine is equipped with a leak detection device. When leaking is
detected the dispense operation will be cut off automatically.
4
5
HOT
6
To reset:
Unplug the machine.
Locate the source of leakage
and rectify.
Locate the detection probe which
can be found in the bottom rear
left hand corner. Dry the probes
and internal area with a dry cloth.
If enhanced Leak Detector is
fitted as optional extra: locate
the Leak Detector valve.
Reset the red lever (push it in).
Reconnect the power to machine
and test operation.
1
2
3
If leak detector is fitted as optional extra, reset the red lever (push it in)