Inside the inlet opening pull the filter replacement
cover out of the filter housing opening (To remove the
filter replacement cover see Fig. 8.5).
1
2
5
4
3
Fig. 8.4
Air guiding housing
[1]
Air guiding housing
[2]
Housing base
[3]
Spigot
[4]
Sealing groove
[5]
Lock
X
X
Hold the housing base [2] with one hand.
X
X
Release the 6 locks [5] around the edge of the base.
X
X
Remove the housing base [2].
X
X
Clean the air guiding housing [1] and the housing base
[2] with a mild cleaning agent.
8.5.2 Closing the air guiding housing
X
X
Position the housing base [2] under the air guiding
housing [1] with the help of the 3 spigots[1].
X
X
Push the housing base [2] upwards into the sealing
groove [4].
X
X
Close the 6 locks [5].
X
X
Check that the housing base is positioned correctly.
X
X
Inside the inlet opening push the filter replacement
cover until it comes to a stop in the filter housing
opening (To insert the filter replacement cover see Fig.
8.11).
X
X
Check that the filter replacement cover is positioned
correctly.
X
X
Insert the stainless steel grease filter and the air inlet
nozzle.
Cleaning in the dishwasher
X
X
Remove coarse food residues from the stainless steel
filter
X
X
Rinse the air inlet nozzle and stainless steel grease
filter with a rinsing program at maximum 65 °C.
8.4.3 Fitting the components
Inserting the stainless steel grease filter
X
X
Take hold of the stainless steel grease filter by the
handle [2].
X
X
Insert the stainless steel grease filter [1] in the inlet
opening [3]. A lock is not provided or necessary.
Inserting the air inlet nozzle
X
X
Insert the air inlet nozzle in the inlet opening.
X
X
Make sure it is positioned correctly.
8.4.4 Removing liquids from the device
Any liquids that flow into the device through the inlet
opening are caught by the stainless steel grease filter
(up to 150 ml) and in the air guiding housing. Do the
following:
X
X
Switch off the fan and deactivate the after-run function
(see Operation chapter).
X
X
Remove the air inlet nozzle and stainless steel grease
filter (see Cleaning and Maintenance chapter).
X
X
Empty the stainless steel grease filter.
X
X
Check whether any liquid has gathered in the base of
the air guiding housing.
X
X
If necessary, wipe the liquid up from the housing base
from above through the inlet opening using a sponge
or cloth.
X
X
Clean the air guiding housing (see Cleaning and
Maintenance chapter, air guiding housing).
X
X
To dry the odour filter and duct parts respectively,
switch on the cooktop extractor at a minimum power
level of 5.
Q
Q
After 120 minutes the cooktop extractor will
automatically switch to the automatic after-run
function (see Device Description chapter).
8.5 Cleaning the air guiding housing
Grease particles and limescale residues from cooking
vapours can settle on the surface of the air guiding
housing. For this reason, regular cleaning is essential.
The air guiding housing can be found on the bottom of the
cooktop inside the floor unit.
8.5.1 Opening the air guiding housing.
X
X
Make sure that the cooktop and cooktop extractor are
switched off (see the Operation chapter).
X
X
Wait until the fan level indicator shows
0
.
X
X
Remove the air inlet nozzle and stainless steel grease
filter.