Installation

www.bora.com

[1] 

Cooktop

[2] 

Inlet opening 

[3] 

Air inlet nozzle

[4] 

Stainless steel grease filter

[5] 

Worktop cut-out

[6] 

Adhesive tape

X

X

Before inserting the cooktop, remove the air inlet 

nozzle [3] and the stainless steel grease filter [4].

X

X

Remove the protective film from the adhesive tape [6] 

on the front of the telescopic pull-out.

X

X

Use the inlet opening [2] as a handle during insertion.

X

X

Keep the cooktop [1] straight as you lift it into the 

worktop cut-out [5]

X

X

Insert the cooktop [1] into the centre of the worktop 

cut-out [5].

X

X

Precisely align the cooktop.

Information regarding flush installation:

X

X

Make sure that the sealing tape of the cooktop is well 

sealed all the way round.

Information regarding surface mounting:

X

X

Make sure that the sealing tape for the cooktop is flat 

against the worktop.

Height adjustment plates for flush 

installation(optional)

1

2

Fig. 6.34  Height adjustment plates

[1] 

Cooktop

[2] 

Height adjustment plate

1

2

Fig. 6.35  Height adjustment plates

[1] 

Sealing tape

[2] 

Optional height adjustment plates

Q

Q

The height adjustment plates are self-adhesive to 

prevent slipping during installation.

3

4

1

2

Fig. 6.32  Extending the telescopic pull-out.

[1] 

Telescopic pull-out

[2] 

Telescopic pull-out adhesive tape

[3] 

Telescopic pull-out extension PULBTA

[4] 

Adhesive tape for telescopic pull-out extension PULBTA

X

X

Remove the protective film from the adhesive tape [2] 

on the front of the telescopic pull-out [1].

X

X

Attach the extension PULBTA [3] (available as an 

accessory including screws for attachment) to the 

telescopic pull-out [1].

X

X

Remove the protective film from the adhesive tape [4] 

on the front of the extension PULBTA [3].

6.7.3  Inserting the cooktop 

5

4

3

2

1

6

Fig. 6.33  Positioning the cooktop in the centre

Содержание Pure PURA

Страница 1: ...installation instructions X Pure Pure BORA X Pure surface induction cooktop with integrated cooktop extractor exhaust air recirculation PUXA PUXU BORA Pure induction cooktop with integrated cooktop ex...

Страница 2: ...ntents are prohibited unless expressly authorised These operating and installation instructions have been drawn up with the greatest of care But it cannot be ruled out that subsequent technical modifi...

Страница 3: ...ure cut out dimensions PUXA PUXU 28 6 5 2 Pure cut out dimensions PURA PURU 28 6 6 Installing the appliance in exhaust mode PUXA PURA 29 6 6 1 Preparing kitchen units 29 6 6 2 Preparing the cooktop 30...

Страница 4: ...ding housing 52 8 5 1 Opening the air guiding housing 52 8 5 2 Closing the air guiding housing 52 8 6 Replacing the activated charcoal filter 53 8 6 1 Removing the activated charcoal filter 53 8 6 2 I...

Страница 5: ...s The gas connection may only be established by certified engineers They also assume responsibility for proper installation and commissioning of the gas system Tab 1 1 Target groups INFO BORA Holding...

Страница 6: ...ighted with symbols and signal words Safety and warning information is structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Consequences of non compliance X X Measures to...

Страница 7: ...h hot cooking surfaces is not possible X X Do not place any objects on the operating panel or the cooktop extractor air inlet nozzle X X Switch off the appliance after use X X Keep pets away from the...

Страница 8: ...X X When using recirculation mode ensure a sufficient supply of fresh air e g by opening a window X X Ensure a normal and comfortable room climate humidity of 45 60 e g by opening natural ventilation...

Страница 9: ...X X If in doubt contact the manufacturer of your medical device or your doctor WARNING Risk of burns from hot objects The cooktop and its exposed parts are hot when the cooktop is in use and during th...

Страница 10: ...ders oven gloves WARNING Risk of injury when opening the bottom housing cover There is a risk of injury while the fan is turning X X Switch off the cooktop extractor and the cooktop X X Turn off the m...

Страница 11: ...sure that the connection cable does not become trapped or damaged CAUTION Lifting heavy loads can cause back injuries If not handled correctly removing and installing the appliance can cause injuries...

Страница 12: ...enever possible clean the cooktop after every use X X Clean the cooktop only after it has cooled down X X When cleaning only use non abrasive detergents to prevent scratching and abrasion on the surfa...

Страница 13: ...e with an external timer or a separate remote control system remote operation Any use other than that specified in these operating and installation instructions or any use that goes beyond that which...

Страница 14: ...lation system PUXU Power levels 1 9 P Recirculation connection WxH 445 x 137 mm Recirculation filter PUXU Maximum filter capacity 150 1 year Tab 3 1 Technical data X Pure PUXA PUXU 3 2 Pure PURA PURU...

Страница 15: ...view 6 68 199 233 802 Fig 3 5 PUXU device dimensions front view 487 63 485 Fig 3 6 PUXU device dimensions side view Device dimensions PUXA 230 290 R 3 40 515 830 230 230 175 27 5 Fig 3 1 PUXA device...

Страница 16: ...iew 6 199 68 196 5 732 Fig 3 11 PURU device dimensions front view 487 63 485 Fig 3 12 PURU device dimensions side view Device dimensions PURA R 3 515 760 444 255 120 340 175 158 Fig 3 7 PURA device di...

Страница 17: ...61591 Sound power level Level 1 minimum 41 2 dB A 40 1 dB A 60704 2 13 Level 9 maximum 66 4 dB A 65 8 dB A 60704 2 13 Power setting 68 6 dB A 67 7 dB A 60704 2 13 Sound pressure level additional deta...

Страница 18: ...ption 5 2 System description 5 2 1 Structure 2 1 4 5 3 6 Fig 5 1 Cooktop 1 Air inlet nozzle 2 Stainless steel grease filter 3 Cooktop 4 Inlet opening 5 Fan 6 Operating panel 1 2 Fig 5 2 Back view of P...

Страница 19: ...s button Decreasing values Fan button Activating deactivating the automatic extractor function cancelling the after run function Timer button Setting the cooking zone timer Warming button Activating d...

Страница 20: ...used For hygiene and health reasons the activated charcoal filter must be replaced at the recommended intervals see the Cleaning and maintenance chapter INFO In recirculation mode ensure sufficient ve...

Страница 21: ...th a cooling fan The cooling fan switches on automatically if the cooktop is used intensively You will hear a whirring sound The cooling fan may continue running after the device has been switched off...

Страница 22: ...mode Q Q F is displayed in the multi function display Q Q The filter service display is shown every time the cooktop extractor is switched on and remains active until the filter has been changed and...

Страница 23: ...maximum cooking zone power is available for a predefined time Q Q The available power is focused on the selected cooking zone meaning that the max power of the second cooking zone on that side is auto...

Страница 24: ...e power setting a maximum power level of 7 can be selected in the front cooking zone max power level 8 on Pure Q Q If the power level selected for the second cooking zone is too high P will blink thre...

Страница 25: ...n the exhaust air mode and a fireplace dependent upon the air supply in the room INFO The state and regional laws and regulations must be observed with regard to the exhaust duct design INFO A suffici...

Страница 26: ...interface it is possible to establish a connection to other systems and for example a window contact switch or low pressure warning device can be connected The module is to be integrated in the cookt...

Страница 27: ...ensions X X Make sure that the cutting surfaces of the worktops are properly sealed X X Comply with the instructions of the worktop manufacturer 6 4 3 Minimum unit dimensions for X Pure PUXA PUXU 199...

Страница 28: ...2 600 Fig 6 14 Cut out dimensions for surface mounting 10 10 40 Fig 6 15 Overlay dimensions for surface mounting 6 5 1 X Pure cut out dimensions PUXA PUXU X Pure flush installation PUXA PUXU x 834 2...

Страница 29: ...PURA INFO The state and regional laws and regulations must be observed with regard to the exhaust duct design A sufficient air supply must be ensured INFO The exhaust air must be directed to the outs...

Страница 30: ...mation regarding flush installation X X Make sure that the sealing tape of the cooktop is well sealed all the way round Information regarding surface mounting X X Make sure that the sealing tape for t...

Страница 31: ...ct system 1 Seal 2 Duct part 3 Exhaust opening X X Pull the seal 1 onto the exhaust opening 3 on the device The seal 1 will need to be stretched slightly X X Push the duct part to be connected 2 with...

Страница 32: ...for the vertical return flow of the recirculation air INFO A return flow aperture 500 cm2 must be provided in the kitchen units 6 7 1 Preparing kitchen units Q Q The floor unit must have a continuous...

Страница 33: ...40 0 10 20 30 40 0 10 20 30 40 0 Fig 6 28 Template for back wall cut out X X Position the template on the back wall of the unit with the help of the markings and instructions INFO Centre of cut out ho...

Страница 34: ...tape for the cooktop is flat against the worktop Height adjustment plates for flush installation optional 1 2 Fig 6 34 Height adjustment plates 1 Cooktop 2 Height adjustment plate 1 2 Fig 6 35 Height...

Страница 35: ...escopic pull out 1 fits accurately is flush with the cut out on the back wall of the unit 3 and closes it off X X Secure the telescopic pull out 1 to the back wall of the unit 3 using the adhesive tap...

Страница 36: ...the filter replacement cover is positioned correctly 6 8 Establishing the power connection X X Observe all safety and warning information see the Safety chapter X X Observe all national and regional l...

Страница 37: ...am see Fig Connection diagram or underside of appliance X X For a one phase or two phase connection connect the relevant contacts using the bridge provided in scope of delivery X X Secure the connecti...

Страница 38: ...m The extraction system must be configured There are two operating modes to choose from Q Q Operating mode 1 Recirculation system factory setting Q Q Operating mode 2 Exhaust air system Fig 6 49 Displ...

Страница 39: ...ealer and service menu When you have been through all of the basic configuration menu items X X Long press on the multi function display Q Q The standard display appears 6 9 2 Function test X X Carry...

Страница 40: ...power button Q Q The switch on animation is displayed in the slider Q Q If start up is successful the standard display will appear in the operating panel Fig 7 1 Standard display after switching on I...

Страница 41: ...uired power level X X By tapping or Q Q The fan symbol lights up and the set fan power level is shown in the multi function display 7 3 4 Childproofing feature Q Q After switching on the appliance the...

Страница 42: ...el is reached Reducing the power level X X Tap the required cooking zone X X Tap a lower position on the slider or X X swipe downwards to the required power level or X X tap until the required power l...

Страница 43: ...be disabled and the cooking zones will be deactivated 7 5 3 Automatic heat up function INFO The system automatically determines the heating time depending on the power level set Activating the automa...

Страница 44: ...Long press on the timer button or Activating the bridging function X X Tap both cooking zones at the same time Q Q The bridging function is now active Q Q The light that looks like a hyphen goes out...

Страница 45: ...the system flashes the remaining time Q Q In the last 5 seconds of the countdown an acoustic signal can be heard every second Q Q The time display 000 and the timer button flash Q Q After the end of...

Страница 46: ...the corresponding slider segment X X Move to another menu item or close the menu 7 6 2 Menu item 2 Childproofing feature INFO With menu item 2 the childproofing feature can be permanently switched on...

Страница 47: ...ognition Activating permanent pan size recognition X X Tap the top slider segment Q Q The pan size recognition symbol v is displayed on all cooking zones for one second Q Q on is displayed X X Move to...

Страница 48: ...nctions are permanently deactivated and are not displayed 7 6 6 Menu item 8 Show software hardware version Fig 7 9 Menu item 8 Software hardware version Q Q The software hardware version is shown via...

Страница 49: ...nables all settings in the customer menu to be reset to the factory settings Fig 7 12 Menu item 0 Factory settings Resetting to factory settings X X Long press on the slider zone Q Q The reset is star...

Страница 50: ...gents or agents containing acid or lye 8 2 Cooktop and extractor care X X Never use the cooktop as a work or storage surface X X Do not push or pull cookware over the cooktop X X Always lift pots and...

Страница 51: ...aser in one X X Rinse the air inlet nozzle and stainless steel grease filter with hot water X X Use a soft brush to clean the air inlet nozzle and stainless steel grease filter X X After cleaning rins...

Страница 52: ...opening 3 A lock is not provided or necessary Inserting the air inlet nozzle X X Insert the air inlet nozzle in the inlet opening X X Make sure it is positioned correctly 8 4 4 Removing liquids from...

Страница 53: ...Replacing the activated charcoal filter An activated charcoal filter will only be fitted with the stainless steel grease filter if the cooktop extractor is used in recirculation mode The activated cha...

Страница 54: ...Tilt the activated charcoal filter towards you slightly and insert it through the inlet opening X X Guide the left end of the filter into the opening in the filter housing Fig 8 10 Placing the activat...

Страница 55: ...maturely The overheating protection has tripped see the Appliance Description chapter The cooktop cooling fan continues to run when the cooktop has been switched off The cooling fan runs until the coo...

Страница 56: ...ng protects the device from damage in transport The packaging materials have been selected from environmental and disposal perspectives and are therefore recyclable Returning the packaging to the mate...

Страница 57: ...manufacturer s warranty shall be assumed by BORA Expressly not covered by the BORA manufacturer s warranty are Q Q BORA products that were not sold by authorised BORA dealers Q Q Damage caused by non...

Страница 58: ...3 3 Air inlet nozzle red PUEDR 3 3 Air inlet nozzle jade green PUEDJ 3 3 Air inlet nozzle orange PUEDO 3 3 Air inlet nozzle blue PUEDB 3 3 Side frame USL515 3 3 3 3 Side frame All Black USL515AB 3 3...

Страница 59: ......

Страница 60: ...derndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Innstra e 1 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora co...

Отзывы: