Troubleshooting

www.bora.com

8  Troubleshooting

Observe all safety and warning information (see the Safety chapter).

Operating situation 

Cause

Remedy

The cooktop cannot be switched on.

The fuse or the automatic circuit breaker of the 

electrical installation of the apartment and/or 

house is defective.

Replace the fuse.

Switch the safety cut-out back on.

The fuse or the automatic circuit  

breaker trips several times.

Call the BORA Service Team.

The power supply is disconnected.

Have a specialist electrician inspect the 

power supply.

Odours and vapours arise when the new 

cooktop is put into operation.

This is normal on brand-new appliances.

Wait a few operating hours.  

Contact the BORA Service Team if the 

odour persists.

v

 is displayed in the cooking zone indicator. No or unsuitable cookware has been placed on 

the cooking zone.

Only use suitable cookware.  

Select the cookware size  

depending on the cooking zone  

(see the Device Description chapter).

L

 is displayed in the cooking zone indicator. The child safety lock is activated.

Switch off the childproofing feature  

(see the Operation chapter).

/

 is displayed in the cooking zone indicator. Permanent activation of a knob.

Cable break between cooktop and control box.

Put the knob back into position.

Call the BORA Service Team.

E

 is displayed in the cooking zone indicator. The associated cooking zone or a power  

element is defective.

Note down the error number and  

contact the BORA Service Team.

A cooking zone or the entire cooktop swit-

ches off automatically.

The operating time of a cooking zone has  

been exceeded.

Put the cooking zone back into  

operation (see the Operation chapter).

The overheat protection has tripped.

(see the Device Description chapter)

The power setting is automatically shut off 

prematurely.

The overheat protection has tripped.

(see the Device Description chapter)

The cooling fan continues running after the 

cooktop has been switched off.

The fan will continue to run until the cooktop  

has cooled down and will then switch off  

automatically.

Wait until the fan switches off  

automatically.

Tab. 8.1  Resolving a fault

X

X

In all other instances, call the BORA Service Team (see the Warranty, service and spare parts chapter).

Содержание PC32

Страница 1: ...EN PFI11UMEN 001 www bora com Operating and installation instructions PFI11 Surface induction glass ceramic cooktop with 2 cooking zones 1037277...

Страница 2: ...heimer Str 33 83064 Raubling Germany Contact T 49 0 8035 907 240 F 49 0 8035 907 249 info bora com www bora com The distribution and duplication of this document as well as the use and disclosure of i...

Страница 3: ...ctions 15 5 3 1 Safety distances 15 5 4 Cut out dimensions 15 5 5 Installing the cooktop 17 5 5 1 Installing the control box behind the floor unit fixed front panel 17 5 5 2 Installing the cooktop 18...

Страница 4: ...ce with these documents nor by improper assembly The electricity and gas connections must be implemented by a certified engineer Assembly must only take place in compliance with the applicable norms r...

Страница 5: ...hazardous situation which causes death or serious injury if not respected Warning Indicates a potentially hazardous situation which can cause death or serious injury if not respected Caution Indicate...

Страница 6: ...d into the room air INFO In the recirculated air mode only a small amount of moisture is removed from the cooking vapours XMake sure that the room is sufficiently ven tilated to the outside air in the...

Страница 7: ...ons The device can constitute a hazard XDo not make any changes to the device Cleaning and Maintenance The device must be cleaned at regular intervals Dirt can lead to damage or odour nuisance Remove...

Страница 8: ...alled protective conductor system Make sure that these basic safety precautions have been taken WARNING Risk of burns caused by hot objects The cooktop and its touchable parts become hot when the cook...

Страница 9: ...onnecting the device incorrectly to the mains poses a risk of electric shock XMake sure that the device has a fixed connection to the mains voltage XMake sure that the device is connected to a properl...

Страница 10: ...emote control system Not using the device as described in this operating and assembly manual is considered not using the device as intended as is using it beyond the purpose described here BORA shall...

Страница 11: ...essories packaging 9 7 kg Cooktop Power levels 1 9 P Front cooking zone power setting 205 x 230 mm 2100 W 3700 W Back cooking zone power setting 205 x 230 mm 2100 W 3700 W Cooktop energy consumption F...

Страница 12: ...el and operating principle 2 4 5 1 3 Fig 4 2 Control knob 1 Operating indicator light 2 Control knob for the front cooking zone 3 Power level sleeve 4 Control knob for the back cooking zone 5 Operatin...

Страница 13: ...cated underneath an induction cooking zone If the cooking zone is switched on this coil creates a magnetic field that acts directly on the base of the pot thus heating it up The cooking zone is only i...

Страница 14: ...rature monitoring of the hob caused by the air gap between the cookware and the temperature sensor underneath the hob overheating may occur The bottom of the cookware must not have any sharp grooves o...

Страница 15: ...ervice immediately X X Do not under any circumstances install parts which are damaged X X Dispose of transport packaging in the proper manner see the Decommissioning and Disposal chapter 5 2 Tool and...

Страница 16: ...1088 1 1 485 457 2 1 856 828 3 2 1338 1310 4 2 1709 1681 Tab 5 2 Cut out dimensions Worktop overhang 74 x Fig 5 2 Worktop overhang X X Please note the worktop overhang x when creating the worktop cut...

Страница 17: ...tween the built in appliances INFO A gap of two millimetres should be planned around the built in appliances INFO The mounting rail supplied with the cooktop should be installed between the cooktops a...

Страница 18: ...ess of adjustment plates mm Adjustment plates quantity 10 mm 5 mm 3 mm 2 mm 34 2 1 33 3 1 32 4 2 31 5 1 1 30 6 2 29 7 1 1 28 8 1 1 27 9 1 2 26 10 1 25 11 1 2 24 12 1 1 23 13 1 1 22 14 1 2 21 15 1 1 20...

Страница 19: ...be done by an authorized member of the After Sales Service team Establishing the power connection X X Switch off the main switch automatic circuit breaker before connecting the cooktop X X Protect th...

Страница 20: ...nstallation is done X X Explain the important functions to the user X X Explain all safety relevant aspects of operation and handling to the user X X Provide the user with the accessories and operatin...

Страница 21: ...ing zone is still hot INFO Turn the cooking zone off after use Do not rely on the pan size recognition X X Turn the control knob to power level 0 to switch off the cooking zone Q Q The operating indic...

Страница 22: ...The cooking zone will automatically switch off after 2 seconds 6 1 8 Switching the childproofing feature on off INFO If a cooking zone indicator alternates between displaying L and H the cooking zone...

Страница 23: ...ing wipes made of fabrics or paper are sucked in see operating instructions for the cooktop X X Make sure that the cooktop is switched off see the Operating chapter X X Wait until all cooking zones ar...

Страница 24: ...tor The child safety lock is activated Switch off the childproofing feature see the Operation chapter is displayed in the cooking zone indicator Permanent activation of a knob Cable break between cook...

Страница 25: ...mentally friendly way Disposal of transport packaging INFO The packaging protects the device against transport damages The packaging is made of materials that are environmentally friendly and easy to...

Страница 26: ...aults you cannot fix yourself contact your BORA specialist supplier or the BORA Service Team The After Sales Service will require the type designation and the serial number of your device FD number Th...

Страница 27: ......

Страница 28: ...orf sterreich T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Prof Dr Anton Kathrein Stra e 3 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 6225...

Отзывы: