5
We reserve all rights of ownership and exploitation in respect of these
documents, including industrial property rights. These documents may only
be used with our express consent in writing, and only to the extent permitted
in any such consent. The documents may not be duplicated or made
available to third parties. In case of violation of the aforementioned
provisions, we reserve all rights.
1 Technical
data
1.1 Density transducer type DIMF 2.0
Density range
0 to 5000 kg/m³
Calibration range
400 to 2000 kg/m³
(Standard)
see Configuration Data Sheet supplied
Accuracy better
than
±
0.02 % (
±
0.2 kg/m³)
(Standard)
(under reference condition)
see Configuration Data Sheet supplied
Repeatability better
than
±
0.005 % (
±
0.05 kg/m³)
Temperature range of liquid
- 40°C to + 150°C
(Standard)
see Configuration Data Sheet supplied
Temperature influence without
approx. 2,8 kg/m³/°C
compensation
Temperature compensation
via integral Pt1000
in acc. with DIN Class A
directly in the transmitter
Pressure influence
less than 0.02 kg/m³/bar
Operating pressure
100 bar
(Standard)
see Configuration Data Sheet supplied
Liquid pumpable
liquids
see Configuration Data Sheet supplied
Material: wetted parts
1.4571
(Standard)
see Configuration Data Sheet supplied
Material: transmitter housing
made of 1.4571
Smallest inside diameter
∅
10 mm
Specialties
Gasket-free construction
on request. Material certificates
in acc. with DIN ISO10204-3.1B;
see Configuration Data Sheet supplied
Weight
approx. 4.2 kg
Process connections
Swagelok fittings for
outer pipe diameter 12 mm
(Standard)
see Configuration Data Sheet supplied
All percentages are referenced to a density of 1000 kg/m³.
For the exact specification of the device version, see the Configuration Data Sheet of the device
supplied.