Important: Before removal from the installation, ensure all electrical, product and 
gas

 

connections are disconnected.

 

 

Disposal of Scrap Units 

 

It is illegal to simply scrap a refrigeration unit. Before a unit can be scrapped it must first 

have  the  gas  removed  by  a  specialist  using  special  equipment.  Please  contact  Vero 
Water for guidance. 

 

Transportation

 

 

Important

: This unit must be transported in an upright position 

 
As with all refrigeration systems, irreparable damage can be caused by laying the unit on 

its side or even transporting upside down. Where the unit is transported by a carrier, the 
carton should always be marked in a conspicuous manner, the correct upright position 

in which it must be handled. 
 

If a unit has been transported incorrectly it should be placed in the correct upright position 
and left for 24 hours before attempting to run the system. 
 

Failure to observe the above precautions could seriously damage the system, and would 
void any warranty.

   

 

 

 

 

 

 

 

 

 

Removal, Transportation and Disposal 

 

Содержание TRM9HC

Страница 1: ...Product Manual TRM9HC Water Cooler Part Number 3B8108 Issue OR ...

Страница 2: ... or other restriction Where components are replaced the new component must be of the same type Operate the unit within ambient operating temperatures 16 C to 38 C Introduction The TRM9HC is a dry block chiller designed to provide chilled still water by passing water through a stainless steel water coil in the cold block The TRM9HC in standard configuration is designed as a single product chiller w...

Страница 3: ...ssor Cubigel NLY12RAa Dry Weight 27Kg This product contains fluorinated greenhouse gas with a GWP of 3 in an hermetically sealed system Supply 220 240Vac 50Hz Climatic Class N Power Consumption 168W Refrigerant 290a 55g 0 055Kg Introduction and Specification ...

Страница 4: ...ispense until all air has been purged from the system 6 Once all air has been purged from the system connect the unit to the electrical supply and turn on After a short delay the compressor and fans will start 7 After approximately 10 minutes the compressor and fan will stop as the chiller has reached its normal operating temperature Note The time taken for the chiller to reach operating temperatu...

Страница 5: ...ponent ensuring that the whole area has been covered Finish the clean by exchanging the cleaning agent for warm water remove the soil with a multi purpose disposable cleaning cloth and dry the component with disposable paper towels Food Grade Antibacterial Wipe Remove the dispense components wipe the dispense component with the food grade antibacterial wipe remove all visible soil Replace dispense...

Страница 6: ...mmended that the procedure is performed during initial installation and at least every 3 months Prepare the Unit 1 Disconnect the electrical power to the unit and isolate from the water supply 2 Carefully follow the manufacturer s instructions and prepare a solution of proprietary sanitizing fluid Sanitize the Water System 3 Disconnect flexible water inlet tube from the water supply and place the ...

Страница 7: ...7 Electrical Schematic ...

Страница 8: ...8 Water Schematic ...

Страница 9: ...ble Cause Corrective Action No Water Dispensing Frozen block Thermostat capillary not fully inserted into chiller block Thermostat out of calibration or faulty Replace if necessary Warm Drinks Insufficient air flow through the fridge Check supply to cooling fans 220 240v AC If supply present replace fans If supply not present move on to the compressor The supply to the fans and the compressor are ...

Страница 10: ...10 Spare Parts 1A6794 Eliwell Controller 3B7692 Fans 1B6430 Power Switch ...

Страница 11: ...upright position As with all refrigeration systems irreparable damage can be caused by laying the unit on its side or even transporting upside down Where the unit is transported by a carrier the carton should always be marked in a conspicuous manner the correct upright position in which it must be handled If a unit has been transported incorrectly it should be placed in the correct upright positio...

Страница 12: ...12 Booth Dispensers Ltd Moor Park Avenue Blackpool Lancashire FY2 0LZ UK 44 1253 501800 ...