OIM - Manual
Version:
2014/11
Speedlane 900
Edition:
SL900 -OIM - USA
10
Changing the frequency inverter parameter set
WARNING!
Risk of personal injury or loss of life.
CAUTION!
The material may be damaged or the operation of the product affected.
The main parameters are factory set by Boon Edam.
The supplier of the FI sets all other parameters.
NOTE!:
Changing the parameter set should only be carried out when troubleshooting has revealed
that the Speedlane 900 is free from any malfunctions.
NOTE!:
Only a limited number of parameters may be changed.
It is important to know that not all parameters are given here. Each Speedlane 900 type has a
different parameter set to give the best operation.
Type
900
900-H 900-W
900-L
900-HW 900-HL
900-LW 900-HLW
Standard
X
High
X
X
X
X
Wide
X
X
X
X
Long
X
X
X
X
Variations of the Speedlane 900
General parameter description is given.
No.
Function
Description
Unit
Pr.00
Start up boost
Start up boost setting
%
Pr.01
Maximum speed
Maximum speed setting
Hertz
Pr.02
Minimum speed
Minimum speed setting
Hertz
Pr.03
Voltage Pr.19 by Freq.
Frequency at voltage Pr.19
Hertz
Pr.19
Voltage by Freq. Pr.03
Voltage at frequency Pr.03
Volt
Pr.125 Terminal 2 gain
Change the frequency at maximum analog input
Hertz
General parameter description