background image

Warnings and safety notes

Never  leave 

BLACKMAX

  unsupervised  during  the  Charge/Discharge  process.  If  any 

abnormal  charging  characteristic  is  observed,  immediately  terminate  the  process  and 

refer to the operation manual.
To maximise the life of your 

BLACKMAX charger 

keep it away from dust, damp, rain, 

heat direct sunshine and vibration. Be careful not to drop your 

BLACKMAX charger

The 

BLACKMAX 

circuitry will operate when powered from a 10-18V DC only. AC power 

is possible with the optional 

Booma-RC

 

BLACKMAX

 AC power adaptor.

This unit and the battery to charge or discharge should be set up on a heat-resistant, 

non-inflammable and non-conductive surface. Never place them on a car seat, carpet or 

similar. Keep all the inflammable volatile materials well away from operating area.

It  is  your  responsibility  to  understand  the  chemistry  of  the  battery  to  be  charged  or 

discharged.  If  incorrect  battery  chemistry  is  selected  the  battery  can  be  damaged  or 

destroyed  and  fire  may  result.    Please  read  and  thoroughly  understand  the  following 

battery information.

NiCd/NiMH 

Voltage level:1.2V/cell 

 

 

Allowable fast charge current:1C-2C depends on the performance of cell  

 

 

Discharge voltage cut off level 0.85V/cell(NiCd), 1.0V/cell(NiMH) 

Lilo

     

Voltage level:3.6V/cell.

 

 

Max.charge voltage:4.1V/cell.

 

 

Allowable fast charge current: 1C or less.

 

 

Min.discharge voltage cut off level:2.5V/cell or higher.

LiPo

    

Voltage level:3.7V/cell.

 

 

Max.charge voltage:4.2V/cell.

 

 

Allowable fast charge current: 1C or less.

 

 

Discharge voltage cut off level:3.0V/cell or higher.

Life (A123)

 

Voltage level:3.3V/cell

 

 

Max.charge voltage:3.6V/cell

 

 

Allowable fast charge current: 4C or less(e.g. A123M1)

 

 

Discharge voltage cut off level:2.0V/cell or higher

Pb

  

 

Voltage level:2.0V/cell

 

 

(Lead-acid) max.charge voltage:2.46V/cell

 

 

Allowable fast charge current:0.4C or less

 

 

Discharge voltage cut off level:1.50V/cell or higher

To avoid short-circuits when connecting batteries to 

BLACKMAX

, always connect the 

charge cable to the unit first and only then to the battery.

Содержание BLACKMAX

Страница 1: ...harger discharger with built in balancer computerised with microprocessor and specialised operating software Please read this operating manual before attempting to use your new Booma RC BLACKMAX charg...

Страница 2: ...generated during the Charge Discharge process can be easily maintained Individual voltage balancer for Lithium batteries BLACKMAX also offers an individual Lithium cell voltage balancer The accuracy...

Страница 3: ...cess by monitoring a user defined maximum charge time Once the charge time is reached the charge process is automatically terminated Input power monitor BLACKMAX monitors the input voltage to it s sys...

Страница 4: ...harger if batteries are connected incorrectly When charging using the balance program please connect the balance connector of the battery pack to the 2 3 4 5 or 6 cell balance connector and then conne...

Страница 5: ...istry is selected the battery can be damaged or destroyed and fire may result Please read and thoroughly understand the following battery information NiCd NiMH Voltage level 1 2V cell Allowable fast c...

Страница 6: ...atteries should never be deep discharged to lower than the minimum manufacturers recommended voltage Generally you do not need to discharge Lithium battery packs Some NiCd and NiMH batteries are said...

Страница 7: ...Program Flow Chart...

Страница 8: ...GRAM Press the Enter key to display the chemistry type Press the Enter again key and the battery cell voltage should blink Press the INC or DEC keys to change the Lithium battery voltage and type Ther...

Страница 9: ...rature or PC functionally in the USER PROGRAM setting To run the PC software you will need to install the software and USB driver prior to connecting the BLACKMAX BRC6 to your PC Temperature monitorin...

Страница 10: ...discharging Lithium batteries with a nominal voltage of 3 3V 3 6V and 3 7V per cell These batteries have a different charge technique termed constant voltage CV and constant current CC method The char...

Страница 11: ...s mode charger will monitor the voltage of each cell of the battery pack and adjust charging current that is feeding to each cell This is balance charging and this mode will give you maximum life of y...

Страница 12: ...st Charge process Starting the charge process is the same as balance and normal charging The screen shows the present situation during charge process To stop charging press Batt type Stop key once STO...

Страница 13: ...ing a balance charge discharge the processor monitors the voltage of individual cells for storage mode and discharge of Lithium battery packs If the cells are well matched and in good condition BLACKM...

Страница 14: ...the early stages of the charge process 2 Manual program mode will charge the pack at the user set current and sense the Delta Peak value of the battery pack to stop the charge process Each mode can be...

Страница 15: ...op key once At the end of the process by pressing the INC or DEC button you can see charged or discharged capacity of the battery for each cycle Pb lead sulphuric acid battery program The Pb lead sulp...

Страница 16: ...uring the process Once you change the value store it by pressing Start Enter button again Save Data Program BLACKMAX comes with 5 user programmable memories for you to store your battery charge discha...

Страница 17: ...on for more than 3 seconds to store the data in the selected memory Load Data Program Your previously saved programs can be recalled from memory To load a previously saved program 1 Press the Batt Typ...

Страница 18: ...pective of whether the battery is fully charged USB Temp Assigns the data port as USB connect to a PC or temperature measurement requires the use of the temperature probe If the temperature function i...

Страница 19: ...required input level The voltage of the battery pack was selected incorrectly Please check the cell count of the battery pack An internal software hardware malfunction has occurred Please contact Boo...

Страница 20: ...ry cell count 1 15cells Lithium battery cell count 1 6Series Pb battery voltage 2 to 20V Weight 400g Dimension 135 100 40mm Warranty and service Booma RC warrants BLACKMAX for a period of one year 12...

Отзывы: