Page 7
3BE390845NI – 01/12
BONNET GRANDE CUISINE
Registered office:
Rue des Frères Lumière - Z.I Mitry Compans
F-77292 MITRY MORY Cedex
3 INSTALLATION: LOCATING
3.1 ASSEMBLING UNITS CANTILEVERED OFF A WALL
3.1.1 FREE STANDING UNITS
Drilling plan
892
16
212
131
400
800
1000
1200
41
41
41
41
41
41
41
41
100
100
200
100
200
200
200
100 100
200
200
200
200
100 100
200
200
200
200
200
100
1118
918
718
318
15
385
400
400
400
200
400
400
400
385
15
902
The fixing brackets must be able to support a force of 4000 N/m (2 brackets for units that are 400, 600,
800, 1000, 1200 or 1400 wide).
It is advisable, when cantilevering equipment off a concrete wall to comply with the following points:
* The reinforced concrete should be of at least 30 N/mm2 (C20/25) standard
* Use HSA-R M 8 x 75mm rawlbolts or equivalent (2 for cooking tops and 6 for ranges).
* For the rawlbolts mentioned above the hole for each should be 8mm diameter and at least 65mm
deep.
Procedure
- Fit the lower support beam to the wall.
Note: This beam must be level.
- Fix the sheet template supplied to the wall with two 5mm Ø screws. Ensure it is level.
902
212
131