Auto Power Off time 

 

Default

:30

  minutes

     

Setting range

:0~120

  minutes 

 

At the operation mode, press 

seconds while pressing 

  key.

   

is indicated at PV display. 

Push 

is 

indicated at PV display. 

Enter the desired value by 

 key or 

  key at SV display. 

After entering the value, push 

mode. 

 

 

 

 

 

 

 

 

During Auto Power Down mode, 

SV display, this function turn off the power 

of controller automatically when the tip temperature is no change for more than a certain period of 
time you set up, since the controller recognizes that the soldering iron is inactivity. 

If unnecessary, set the value “0” (zero), and this function becomes ineffective.   

 

 

 

 

Exiting Auto Power Down mode 

 

Press 

 

key or 

  key more than 3 seconds to return to the operation mode. 

Temperature deviation by more than 5

  can release Auto power down mode. 

e.g.    Touch the iron tip with a moisturized sponge. 

 

 

 

 

Exiting Auto Power Off mode 

 

Turn on the power again. 

 

 

 

⑥ 

Manual operation 

 

After the tip temperature has reached to the set temperature, at the operation mode, press 

  key or 

  key approx. 3 seconds to enter the power down mode. 

 

At the power down mode, press 

  key or 

  key approx. 3 seconds to release the mode and 

return to the operation mode.

 

 

 

Operation mode 

 

Input screen 

 

Auto Power Down 

time setting screen 

 

Operation mode 

 

 

 

 

Содержание M12

Страница 1: ...M12 LA type soldering iron controller Instruction manual Date prepared April 2018 The 9th edition JAPAN BONKOTE CO LTD PATRIOT ...

Страница 2: ... 7 B Alarm function lower limit setting 8 C Temperature recovery speed setting 8 D Upper limit setting of set temperature 8 E Indication of manipulated output value 9 F Lock function 9 G Anti reset wind up setting 10 H Auto Power Down Auto Power Off setting 10 I PID value manual setting 13 7 List of character 15 8 How to maintenance 16 9 Standard specification 16 10 Guarantee and After sales servi...

Страница 3: ...re or adjacent operations may get hurt Unplug the iron unit and allow sufficient time for it to cool when replacement or maintenance Do not overhaul the machine when the machine has trouble Otherwise it may cause malfunction electric shock and etc death at worse Contact our customer service department and follow instructions to make maintenance Be sure to use proper replacement parts such as fuse ...

Страница 4: ...ctricity removal device wrist strap etc Odor is generated due to the use of solder and flux Be sure to ventilate work places e g Install a ventilation fan etc Be sure to pull out the power plug when the machine is not used Be sure to grab the power plug instead of the cord when plugging and unplugging When change power voltage from 100V to 220V for example make sure to confirm the specifications o...

Страница 5: ... iron NOTE This picture is M12 TB 170J station set 3PCHI plug cord for 100V or 3EPV plug cord for 220V comes with a controller 5 B Name of the body FRONT BACK Power switch Fuse holder 5 pin connector 3 pin inlet PV display working temperature SV display setting temperature key value up key value down key speed setting ...

Страница 6: ...ble the iron stand and store the soldering iron in its holder 1 2 3 5 6 4 No Name Model No 1 Holder B 11 2 Cover 3 Screw with spring washer M4 x 6 4 Cleaner case K 5 5 Cleaner base 6 Cleaning sponge S 6 Assemble order Ⅰ Remove the screw from the cleaner base Ⅱ Align a screw hole of the holder and the cleaner base then tighten the screw Iron stand BON 14 is for TB 1175 iron BON 3 is for TB 1100 BON...

Страница 7: ...ng iron and that of the controller should be the same Otherwise temperature control is unable to work The sensor type of controller and soldering iron is adjusted the same at the shipment The sensor type of controller itself is type K at the shipment 1 How to confirm the sensor type Controller part At the operation mode SV display as show below Check the sensor type of the controller whether it is...

Страница 8: ...Ⅲ Press key once to return to the operation mode Operation modee Setting temp Operation mode Temperature compensation Default 0 Setting range 100 0 100 0 Ⅰ At the operation mode press seconds while pressing key is indicated at PV display Ⅱ Press key 3 times and is indicated at PV display Ⅲ Enter the desired value by key or key at SV display Ⅳ After entering the value push key 4 times to return to ...

Страница 9: ...form with enough effect Auto Tuning completes when AT lamp stops blinking Above and are unnecessary to do every time Do it when iron tips or set temperature are changed At shipment Auto Tuning function has NOT done yet Make sure to do it at the first time to use 6 Optional functions M12 controller has various functions Please use them with your convenience 6 A Alarm function Upper limit setting Se...

Страница 10: ...perature Default 4 0 Setting range 1 0 10 0 Ⅰ At the operation mode press key once and is indicated at PV display Ⅱ Enter the desired value by or key at SV display Ⅲ After entering the value push key once to return to the operation mode Set value 1 0 Recovery speed is fast but overshooting becomes large Set value 10 0 Recovery speed is slow but overshooting becomes small 6 D Upper limit of set tem...

Страница 11: ... to prevent error setting Default Ⅰ At the operation mode press 3 seconds while pressing key PV display Ⅱ Push is indicated at PV display Ⅲ Enter the desired function by key or key at SV display Ⅳ After entering the value push mode LOCK NON Only LOCK FUNCTION is available LOCK FUNCTION and Changing set temperature are available Operation mode Output amount Operation mode Operation mode 1 Input scr...

Страница 12: ... the default can restrain overshooting but there might be possible not to recover to the set temperature 6 H Auto Power Down Auto Power Off In order to prevent soldering iron tips from Deterioration and Oxidization the tip temperature is lowered Power Down and the supplying electric power to the heater is stopped PowerOff automatically when the tiptemperature does not change for a certain period o...

Страница 13: ...lue 0 zero and this function becomes ineffective Auto Power Down temperature Default 150 Setting range 0 set temp 1 Ⅰ At the operation mode press seconds while pressing key is indicated at PV display Ⅱ Push 5 times and is indicated at PV display Ⅲ Enter the desired value by key or key at SV display Ⅳ After entering the value push 2 times to return to the operation modee The tip temperature falls d...

Страница 14: ...ng iron is inactivity If unnecessary set the value 0 zero and this function becomes ineffective Exiting Auto Power Down mode Press key or key more than 3 seconds to return to the operation mode Temperature deviation by more than 5 can release Auto power down mode e g Touch the iron tip with a moisturized sponge Exiting Auto Power Off mode Turn on the power again Manual operation After the tip temp...

Страница 15: ...cated at PV display Ⅱ Push key once and is indicated at PV display Ⅲ Enter the desired value by key or key at SV display then push key 6 times to return to the operation mode Integration time Default 38 seconds Setting range 0 3600 seconds Higher set value can reduce overshoot however it makes temperature recovery time longer and temperature reduction during soldering work larger Ⅰ At the Operatio...

Страница 16: ...y time longer This value is supposed to be set or adjusted after value P and I are almost fixed Ⅰ At the Operation mode press for 3 seconds while pressing key indicated at PV display Ⅱ Push Ⅲ Enter the desired value by key or key at SV display then push return to the operation mode Operation modee Auto Tuning Derivative time Operation mode ...

Страница 17: ...al band Lock function key Integration time Upper limit temp Recovery speed Derivative time Compensation screen key long press Anti reset wind up Auto Power Down time Operation amount output Upper limit alarm Auto Power Down temp Lower limit alarm Auto Power Off time Operation mode Operation mode ...

Страница 18: ...cord 100VAC 3pin 3PCHI plug cord 220VAC 3pin 3EPV plug cord Dimension 97 W 130 D 73 H mm Weight 750 g Fuse 3A Temperature control method PID control Auto Tuning Temperature indication PV display LED RED SV display LED GREEN Error indication Over scale Temperature exceed the upper limit of temperature range Error of sensors Under scale Temperature exceed the lower limit of temperature range Reverse...

Страница 19: ...h the sensor type of controller and soldering iron P5 Auto Tuning function is NOT implemented Implement Auto Tuning function P7 Temperature does NOT reach the set temperature Adjust the value of recovery speed Implement Anti reset wind up function P 8 P10 Overshooting is large Key operation is unable Lock functions are ON Check the lock functions P9 10 B Guarantee Our products are shipped after se...

Страница 20: ... JAPAN BONKOTE CO LTD 600 14 Kasahara Mito Ibaraki 310 0852 JAPAN TEL 81 29 241 2725 FAX 81 29 241 2726 http bonkote co jp Email info bonkote co jp ...

Отзывы: