11
①
Auto Power Down time
Default
:
30 minutes
Setting range
:0
~
120
minutes
Ⅰ
:
At the operation mode, press
seconds while pressing
▽
key.
is indicated at PV display.
Ⅱ
:
Push
is indicated at PV display.
Ⅲ
:
Enter the desired value by
△
key or
▽
key at SV display.
Ⅳ
:
After entering the value, push
key 3 times to return to the operation mode.
This function lowers the tip temperature automatically when the temperature is no change for more
than a certain period of time you set up, since the controller recognizes that the soldering iron is
inactivity. During this mod
alternately.
If unnecessary, set the value “0” (zero), and this function becomes ineffective.
②
Auto Power Down temperature
Default
:150
℃
Setting range
:0
~
(set temp.)
-1
℃
Ⅰ
:
At the operation mode, press
seconds while pressing
▽
key.
is indicated at PV display.
Ⅱ
:
Push
5 times , and
is indicated at PV display.
Ⅲ
:
Enter the desired value by
△
key or
▽
key at SV display.
Ⅳ
:
After entering the value, push
2 times to return to the operation modee.
The tip temperature falls down and stands by at the specific temperature you set up.
e.g. If you set up
「
150
℃
」
, the temperature drops and stands by around
「
150
℃
」
when not in
use. In case the operation temperature is
「
350
℃
」
, Auto Power Down temperature can be set under
349
℃
only.
Operation mode
⇒
Input screen
⇒
Auto power down
time setting screen
⇒
Operation mode
Operation mode
⇒
Input screen
⇒
Auto power down
temp. setting screen
⇒
Operation mode