![bonitron M3612EC Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/bonitron/m3612ec/m3612ec_customer-reference-manual_2787130013.webp)
User’s Manual
13
3.
I
NSTALLATION
I
NSTRUCTIONS
WARNING!
Installation and/or removal of this product should only be performed by a
qualified electrician in accordance with National Electrical Code or local codes
and regulations.
Proper installation of the Power Supply Modules should be accomplished following the
steps outlined below. Be sure to refer to the AC Drive instruction manual as these steps
are performed. Please direct all installation inquiries that may arise during the installation
and start up of this product to the equipment supplier or system integrator.
3.1.
E
NVIRONMENT
The module should be installed in an area protected from moisture and falling debris.
Buildup of dust or debris may cause poor performance and possibly a failure.
Operating in a wet environment can pose a shock hazard. The recommended
temperature range for operating or storing this module is 0
C to +40
C.
3.2.
U
NPACKING
Upon receipt of this product, please verify that the product received matches the
product that was ordered and that there is no obvious physical damage to the unit. If
the wrong product was received or the product is damaged in any way, please contact
the supplier from which the product was purchased.
3.3.
M
OUNTING
3.3.1.
M
OUNTING THE
M3612EC
C
APACITOR
B
ANK
The installation site for the module should be chosen with several
considerations in mind:
The unit requires a minimum clearance of two (2) inches in all directions
around it when mounted near a non-heat source.
Unit should not be exposed to falling debris or condensation.
Once the installation site has been selected as outlined above, the unit
should be mounted in place. The M3612EC must be properly oriented
for proper heat flow through the units. The M3612EC must be mounted
with the rear surface of the unit to the mounting surface.
Unit should be
mounted vertically
as shown in Example A of Figure 3-1.
Do Not
mount the unit upside-down or on the underside of a
mounting surface as shown in Example B of Figure 3-1.
Do Not
mount unit in a horizontal position with its side parallel to the
mounting surface or floor as shown in Example C of Figure 3-1.
Figure 3-1: M3612EC Mounting Orientation
HORIZONTAL TO FLOOR
Example A
HORIZONTAL SURFACE
VERTICAL SURFACE
UP
UP
Example B
Example C
HANGING UNDERSIDE
UP
Dwg: 070131 Rev: 20070225
Содержание M3612EC
Страница 6: ...M3612EC 6 This page intentionally left blank ...
Страница 8: ...M3612EC 8 This page intentionally left blank ...
Страница 12: ...M3612EC 12 This page intentionally left blank ...
Страница 15: ...User s Manual 15 Figure 3 2 Power Connections Dwg 090051 Rev 20120605 ...
Страница 18: ...M3612EC 18 Figure 3 4 M3612EC Capacitor Bank Field Wiring Diagram Option 2 Dwg 090050 Rev 20120605 ...
Страница 20: ...M3612EC 20 This page intentionally left blank ...
Страница 27: ...User s Manual 27 NOTES ...
Страница 28: ...M3612EC 28 This page intentionally left blank ...
Страница 29: ...User s Manual 29 This page intentionally left blank ...
Страница 30: ...M3612EC 30 This page intentionally left blank ...
Страница 31: ......