4.2.3.
T
EST
M
ODE
(P
OSITION
9)
Test mode is used to insure the wiring for the output of the module is correct.
In test mode, the output will cycle on and off at 1 second intervals regardless
of the input.
To enter test mode:
1.
Remove 24V power from the module.
2.
Select
Position “9” on the output selection switch.
3.
Apply 24V power from the module.
4.
Output will cycle.
5.
When finished testing, select a different switch position and cycle power.
Note: Unit will stay in test mode until power is cycled.