39
("9`YWhf]WWiffYbh(r&$a55bU`c[
CihdihCdh]cb!(
The BS-205 series of unit meters can output an analog signal for an indicated
value.(when the meter is equipped with an analog output unit)
The analog output of the BS-205 series allows for arbitrary output scaling.
This scaling can be achieved by setting the indication value for an output of the
maximum scale value(20mA for 4~20mA output range) in the dA.HI parameter of
the scaling data.
The current output occurs proportionally the current according to
the size of a weight In 4~20mA.
OPTION
2
1
3 4
Analog output (0~10V, 4~20mA) option
Pin No.
Name
Description
1
V-OUT
Voltage output terminal (0 to 10V)
2
COM
Common terminal for analog output.
3
COM
Common terminal for analog output.
4
A-OUT
Current output terminal (4 to 20mA)
▣ SPECIFICATION
output Voltage
4 ~ 20 mA DC Current out
Precision
Max 1/1000
Min Impedance
Under 500 Ω