The Hold function temporarily retains the indication. The hold function is
enabled by short circuiting the HOLD and COM terminals or setting both
terminals to the same voltage level. As a result the display unit retains the
indication given at that moment.
Hd.oFF
Hold function
set
OFF(No used)
/P(Peak Hold)/ I(Instant Hold)
OFF
Method of setting Hold data
Press the increment and mode keys together during
measurement.
Press the mode key a nine times to display the hold
mode data menu. Press the increment key a few times
to display the parameter to be set. Press the enter key
to set. Press the enter or mode key to the
measurement mode.
Indication
Setup options
HOLD mode (Hd.oFF / Hold.P/ Hold.I)
1
M
2
3
BONGSHIN
4
High Precision DIGITAL INDICATOR
BS - 205
LO
HI
OK
HOLD
STABLE
ZERO
No used (Hold off)
1
M
2
3
BONGSHIN
4
High Precision DIGITAL INDICATOR
BS - 205
LO
HI
OK
HOLD
STABLE
ZERO
- Peak HOLD -
The peak hold function retains one of the maximum
values and provides output for that value. Selection
from these values is made using the hold function
data.