12.5.3
0x6040/0 Control word
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x6040
0
Control word
Unsigned16
rw
Rx
0
Object 0x6040/0
Control word is relevant to the inverter remote state machine when-
ever parameter
LocalRemote
412 is set to 1 (remote state machine).
Control word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
Switch on
1
Enable voltage
2
Quick stop (Low active)
3
Enable operation
4
Operation mode specific
5
Operation mode specific
6
Operation mode specific
7
Fault reset
8
Halt
9
Operation mode specific
10
Reserved
11
Manufacturer specific
12
Manufacturer specific
13
Manufacturer specific
14
Manufacturer specific
15
Manufacturer specific
Bits 4, 5, 6 and 9 … 15 are used in motion control configurations (p.30 = x40) only.
See chapter 14 “Inverter Control” and 16.1 “Control Word overview”.
Example:
COB ID CB Index SI Data
Read Request
601
40 40 60 00 00 00
Reply
581
4B 40 60 00 01 00
Write Access
601
2B 40 60 00 06 00
Reply
581
60 40 60 00 00 00
CB: Control byte SI: Sub Index All values in hexadecimal without leading 0x
04/13
CM-CAN ACU
115