Accessing data via PROFINET
Operating manual for PROFINET fieldbus | DOC01725815-0003 | 2016-12 | V2.04 EN
35
Continuation
PROFINET
DGM parameter
Slot
Index
Parameter
Number*
Accepted
Name in German
Minimum
Maximum
Unit
1
82
82
3.061
2: Always
PID inverted
0
1
1
83
83
3.062
2: Always
PID fixed nominal
value 1
0
100
%
1
127
127
3.063
2: Always
PID fixed nominal
value 2
0
100
%
1
128
128
3.064
2: Always
PID fixed nominal
value 3
0
100
%
1
129
129
3.065
2: Always
PID fixed nominal
value 4
0
100
%
1
130
130
3.066
2: Always
PID fixed nominal
value 5
0
100
%
1
131
131
3.067
2: Always
PID fixed nominal
value 6
0
100
%
1
132
132
3.068
2: Always
PID fixed nominal
value 7
0
100
%
1
133
133
3.069
2: Always
PID fixed nominal mod
0
2
1
84
84
3.070
2: Always
PID standby time
0
1000
s
1
85
85
3.071
2: Always
PID standby hyst.
0
50
%
1
166
166
3.072
2: Always
PID dry. Time
0
32767
s
1
169
169
3.073
2: Always
PID target value min
0
100
%
1
170
170
3.074
2: Always
PID target value max
0
100
%
1
25
25
4.020
2: Always
AI1 input type
1
2
1
26
26
4.021
2: Always
AI1 standard. Low
0
100
%
1
27
27
4.022
2: Always
AI1 standard. High
0
100
%
1
23
23
4.023
2: Always
AI1 dead time
0
100
%
1
22
22
4.024
2: Always
AI1 filter time
0.02
1
s
1
19
19
4.030
2: Always
AI1 function
0
1
1
103
103
4.033
2: Always
AI1-phys unit
0
10
1
104
104
4.034
2: Always
AI1 phys min
-10000
10000
%
1
105
105
4.035
2: Always
AI1 phys max
-10000
10000
%
Continues next page