12.5.23
0x6070/0 Velocity Threshold Time
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x6070
0
Velocity Threshold Time
Unsigned16
rw
No
0
Object works in:
•
o
Profile Velocity mode
Object doesn’t work in:
•
o
Profile Positioning mode
o
Velocity mode
o
Homing mode
o
Interpolated mode
o
Cyclic Sync Position mode
o
Cyclic Sync Velocity mode
o
Table Travel record mode
o
Move away from Limit Switch
o
Electronic Gear: Slave
•
Non motion Control (conf.
≠
x40)
If the absolute value of the Actual Velocity lies for the time given over 0x6070
Velocity
Threshold Time above the threshold
, the bit is reset. If the
Actual Velocity falls below the defined threshold of
, bit 12
“Velocity” of the Status word is set.
The value range of Object 0x6070/0
Velocity Window Time is 0 … 65535 ms.
Writing to object 0x606F/0
Velocity Window Threshold automatically generates a write
command to parameter
Threshold Window Time
1279 (data set 5, all data sets in RAM
only !).
If object 0x606F/0
Velocity Threshold was written and then a save parameters com-
) processed, the object value is stored in non-volatile memory.
After the next power on of the inverter, the previously set value is reactivated and
overwrites the setting of parameter
Threshold Window Time
1279.
The dimension of the user units is defined by
and
07/13
CM-EtherCAT