12.5.36
0x6092/n Feed constant
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x6092
0
Highest sub-index supported
Unsigned8
ro
No
2
1
Feed
Unsigned32
rw
No 0x1 0000
2
(Driving) shaft revolutions
Unsigned32
rw
No
1
Object works in:
•
o
All modes
Object doesn’t work in:
•
Non motion Control (conf.
≠
x40)
Object 0x6092
feed constant defines the feed (in user units) per driving shaft revolu-
tions.
s
revolution
shaft
driving
feed
0x6092/2
0x6092/1
constant
Feed
=
1
Parameter
1115
Constant
Feed
The allowed value for 0x6092/2
driving shaft revolutions is 1 only. Writing values other
than 1 results in an SDO abort response.
Writing to object
feed or driving shaft revolutions automatically generates a write
command to parameter
Feed Constant
1115 (data set 5, all data sets in RAM only!).
If object 0x6092/1 or 0x6092/2 was written and then a save parameters command
) processed, the object value is stored in non-volatile memory.
After the next power on of the inverter, the previously set value is reactivated and
overwrites the setting of parameter
Feed constant
1115.
The values of Object 0x6092/1 and 6092/2 are limited as follows:
Parameter
Setting
No.
Object
Min.
Max.
0x6092/1 Feed
1
65535
(= 0x0000 FFFF)
0x6092/2 (Driving) shaft revolutions
1
1
=
98
CM-EtherCAT