Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the “off”
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak.
If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
OPERATION
1-866-771-2663 | Page 9
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable).
Pumice stones/lava rocks/LavaGlass
could pop up and
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in
height.
To Light
1. Turn ignition control knob (L ) to the “OFF” position. Connect propane gas tank to regulator
and open the cylinder valve.
2. Push the ignition control knob (L ) in and turn counterclockwise to the “HIGH” position; this
will ignite the fuel.
3. If ignition does NOT immediately take place in seconds, push and turn the ignition control knob
(L ) clockwise to “OFF”. Wait 5 minutes, then repeat the lighting procedure as above.
4.
L ) either clockwise or counterclockwise
To Extinguish
1. Push and turn the ignition control knob (L ) clockwise to the “OFF” position.
2. Turn the propane gas tank valve on the gas tank to close the gas supply and disconnect
the propane gas tank
.
Fire product and propane gas cylinder minimum
distance must be over 60 inches (as per right side
photo).
WARNING
®
Wait 50 minutes after extinguishing flame prior to placing a lid (if applicable) or protective cover on
heating item.
Keep holding down the control knob for 15 seconds.