Note:
• If “60”, “120”, or “180” is chosen,
the scale will turn off after the
designated number of seconds of
inactivity.
• If the Auto-off function is disabled,
the scale will not shut off on its
own.
Note:
To maintain a longer battery life,
please turn off the scale by pressing
the ON/OFF button after each use.
CALIBRATION
1. While the scale is off, press ON/
OFF button to turn on the scale.
‐ The LCD will read “0.0g”.
2. Press and hold the MODE button
until the display shows
3. “CAL”, then release the button.
4. Press MODE button again.
‐ “500g” will flash on the display.
5. Place a 500g calibration weight
onto the center of the platform.
6. The LCD will read “PASS” then
return to the normal weighing
mode.
7. Calibration is complete.
WARNING
MESSAGES
• “LO”: Low voltage
‐ Replace the batteries.
• “EEEE”: Overload
‐ Quickly remove weight from
platform to protect the scale.
• “UNST”:
‐ Scale is not steady during start
up. Please turn off scale, set
on a stable surface and restart
scale.
‐ Water is inside the scale.
Shake out excess water and
let dry.
WASHING
INSTRUCTIONS
This scale has been treated with a
liquid repelling Nano- coating which
allows you to wash your scale without
damaging the internal electronics.
Please follow these instructions when
washing:
1. Hand wash only with mild soapy
water.
2. Wash only the platform. Rinse
other parts with clean water if
needed.
3. After washing the scale, shake out
excess water. It is best to do this
by firmly grasping the scale in one