7.1. Correct Storage
Always store the device in a horizontal position in the original packaging.
In the case of a longer period of interruption from work of up to 12 hours, the
nozzle of the Bona OptiSpread 100 Battery can remain on the machine.
Partially used adhesive foil bags can also remain in the machine. The nozzle
must be cleaned on the outside with Bona Tool Cleaner. The section where
adhesive comes out must be cleaned thoroughly. Toothing must then be
covered with adhesive tape or the entire nozzle must be closed air-tight.
The machine can be stored horizontally or transported in this condition for up
to 24 hours without risk of drying.
In the case of longer storage (> 24 hours) the nozzle must be removed from
the tube. If a foil bag is still in the machine, it must be pressed empty or
removed. The adhesive nozzle is designed as a non-return nozzle and can
be disposed of on completion of the respective project. If required, the nozzle
can be used repeatedly.
Avoid lengthy storage in damp or continuously wet and dusty places.
If the machine has been stored continuously or overnight at a temperature of
under +10°C, the machine first has to
be acclimatized to room temperature (≥
+ 15°C) to ensure safe functioning of the piston.
7.2. Transport
Always transport the OptiSpread 100 Battery in the original packaging
provided.
When transporting the machine, make sure it is not damaged and score and
fasten it to avoid any damage during transport.