8 Technical data
bon E-50
Lifting column (Chair unit)
Power supply
230 V / 50 Hz
Consumption 2.2
A
Safety class
I
Max. load on the axis
1800 N (approx.170kg)
Duty ratio (chair column)
S2 10% based on 10 min.
Lift 215
mm
Speed with load
approx. 16 mm/s
Thermal switch
Yes
Limit switch on/off
Yes
Jumper
Connection
Tabletop unit 1
(TG1)
Connection
Tabletop unit 2
(TG2)
AC1/EIN2
6 V
6 V
AC2/EIN2
12 V
6 V
AC2/EIN2*
12 V
12 V
*Change voltage: Feeder clamp 63 and 64
Fig. 8-2: circuit board (power supply)
Feeder clamp
Name
Description
60
EIN2
Connection for jumper
61
AC1
Connection for jumper
62
AC2
Connection for jumper
63
AC2
Voltage for control: 14 V AC
64
AC1/EIN1
Voltage for control: 8,3 V AC
65
AC0
Output voltage for tabletop unit: Ground
66
AC0
Output voltage for tabletop unit: Ground
67
TG1
Output voltage for tabletop unit 1 (6 V AV / 12 V AC)
68
TG2
Output voltage for tabletop unit 2 (6 V AV / 12 V AC)
70
E_WTEIN
Switching voltage: 12 V AC
71
GND
Switching voltage: Ground
72
12 V DC
Switching voltage: 12 V DC
73
10VAC(SB)
Operating voltage: 10 V AC
74
-
Operating voltage: Ground
75
DP1
Potentiometer adjustable table
76
DP2
Potentiometer adjustable table
77
12V DC
Voltage 12 V DC
GA bon E-50 Rev 1.0 E 211005.doc