POWER PLANT
For Training Purposes Only
May 03
18-11
P I L O T T R A I N I N G G U I D E
Oil Replenishment System
Figure 18-6
System not
Activated
System power
is on
System under test
condition (RH & LH
indicator switch pressed
system is functional)
Selector valve held to "R"
position oil pump running
(RH tank being filled)
Selector valve held to "R"
position oil pump not
running (RH tank is now
full)
Selector valve held to "L"
position, oil pump running
(LH tank being filled & RH
tank full)
Selector valve held to "L"
position, oil pump not
running (LH tank is now full
& RH tank full)
Selector valve
released (both tanks
are full)
System
deactivated
ON
ON
LH FULL
LH FULL
RH FULL
RH FULL
ON
ON
OFF
OFF
ENG OIL
ENG OIL
PRESS
TO TEST
PRESS
TO TEST
ON
ON
LH FULL
LH FULL
RH FULL
RH FULL
ON
ON
OFF
OFF
ENG OIL
ENG OIL
PRESS
TO TEST
PRESS
TO TEST
ON
ON
LH FULL
LH FULL
RH FULL
RH FULL
ON
ON
OFF
OFF
ENG OIL
ENG OIL
PRESS
TO TEST
PRESS
TO TEST
ON
ON
LH FULL
LH FULL
RH FULL
RH FULL
ON
ON
OFF
OFF
ENG OIL
ENG OIL
PRESS
TO TEST
PRESS
TO TEST
ON
LH FULL
RH FULL
ON
OFF
ENG OIL
PRESS
TO TEST
ON
LH FULL
RH FULL
ON
OFF
ENG OIL
PRESS
TO TEST
R
L
R
L
R
L
R
R
L
L
R
L
R
L
R
L
R
L
CONTROL
PANEL
CONTROL
PANEL
SELECTOR
VALVE
SELECTOR
VALVE
OIL LEVEL
CONTROL PANEL
Engine Oil
Replenishment
Tank
Filter Cap
Electric
Pump
Manual
Selector
Valve
Oil Quantity
Indicator
Note:
Engine oil level should be checked within 15 minutes to two hours after engine shutdown
The engines must be dry-motored if the replenishment period is exceeded.
Do not allow more than 1.9 liters (2 U.S. quarts) to flow into the engine without
dry-motoring the engine for at least 30 seconds (prior to adding more oil).
AFT EQUIPMENT BAY
P604_18_018