PL14J1, TEST POINT A
PL14J1, TEST POINT B
CONDITION
P
L
Continuity
P
N
Open Circuit
K
a
Open Circuit
(a) If one of the conditions is incorrect, do the steps that follow:
1 Disconnect the wires from the toggle switch S129.
2 Do a continuity check between the S129 contacts that follow:
S129, TEST POINT A
S129, TEST POINT B
CONDITION
2
1
Continuity
2
3
Open Circuit
5
4
Continuity
5
6
Open Circuit
3 If one of the conditions is incorrect, replace the toggle switch S129. If the conditions are
correct, continue with this procedure.
4 Do a continuity check of the wiring that connects to the toggle switch S129 as follows:
PL14J1, TEST POINT A
S129, TEST POINT B
CONDITION
L
1
Continuity
P
2
Continuity
N
3
Continuity
K
5
Continuity
a
6
Continuity
5 If there is an open circuit, repair/replace the defective wiring. If there is continuity,
continue with this procedure.
6 Connect the disconnected wiring.
(b) If the conditions are correct, continue with this procedure.
(5) Set the NO SMKG ON OFF AUTO toggle switch S129 to AUTO.
B
COMPONENT MAINTENANCE MANUAL
PASS SIGNS/EMER LTS CONTROL PANEL
PART NUMBER CC670−51142−1,−3
33−24−07
Page 1003
Jun 10/2016
Содержание CC670-51142-1