BOMANN KG 210 Скачать руководство пользователя страница 4

04/2012 

  Please keep in mind that the manufacturer is not reliable for any damage resulting from commercial 

or any other use then cooling/freezing food. 

 

Unpacking 

The  packaging  must  be  undamaged.  Check  the  device  for  any  possible  transport  damage.  Do  not 
install a damaged device. In case of damage, please contact your distributor. 

 

 ATTENTION 

Remove the separate polystyrene part (transport protection) between the rear of the device and con-
denser – metal grid (if available).

 

 

Packaging material 

The packaging for transportation of the device and individual parts is produced of recyclable materials. 

  corrugated cardboard / paperboard (mainly of waste paper) 

  form part of PS (foamed, CFC-free polystyrene) 

  Films and bags of PE (polyethylene) 

  Strapping strips of PP (polypropylene) 

 

 IMPORTANT 

Make sure you dispose of packaging materials environmentally friendly. 

 

Removing the transport protection 

The device and  parts of the interior are  protected for  transport. Remove all adhesive tapes from the 
right and left side of the door. You may remove adhesive residue with a cleaning solvent. Also remove 
any adhesive tapes and packaging materials from the inside of the device. 
 
 

P

RODUCT 

D

ESCRIPTION

 

 

BOMANN Model No. 

KG 210 

KG 211 

Energy efficiency class

(1)

 

A++ 

A++ 

Climate class

(2)

 

N/ST 

N/ST 

Gross/net capacity, total 

244 / 227 l 

296 / 279 l 

Net capacity fridge/freezer 

173 / 54 l 

191 / 88 l 

Freezing capacity 

6,0 kg / 24h 

8,0 kg / 24 h 

Storage time by power failure 

max. 18 h 

max. 20 h 

Energy consumption 24 h

(3)

 

0,49 kWh 

0,56 kWh 

Energy consumption year

(3)

 

179 kWh 

204 kWh 

Connection voltage 

220-240 V, 50 Hz 

220-240 V, 50 Hz 

Connection power 

140 W 

140 W 

Operating noise 

40 dB(A) 

40 dB(A) 

Sizes H x W x D 

150,0 x 60,0 x 65,0 cm 

176,0 x 60,0 x 65,0 

Gross / net weight 

55,0 / 59,5 kg 

64,0 / 69,5 kg 

Coolant

(4)

 

R600a (51,0g.) 

R600a (57,0g.) 

(1)

 A++ = economical  -  G= less economical 

(2)

 The Manufacturer guarantees reliable operation of the refrigerator when the relative air humidity not greater  

    than 70% and the ambient temperature is: 
    Climate class N (Normal): ambient temperature of +16 C up to +32 C 
    Climate class ST (Subtropics): ambient temperature of +16 C up to +38 C 

(3)

 The actual energy consumption depends on the use and installation of the device. EC 1060/2010. 

(4) 

The appliance is ecologically clean, containing no material harmful to the ozone layer. The refrigerant used  

     is R600a, the foaming agent used for the appliance insulation is Cyclopentane C

5

H

10

.

 

 

All device-specific data of the energy label have been determined by the manufacturer under laborato-
ry conditions in accordance with pan-European standardized measuring methods. These are regulated 
by ISO EN 15502. The actual energy consumption depends on the usage and might therefore also be 
above the values determined by the manufacturer under standard conditions. 
An  expert knows these relations and  will execute the tests  with special measurement instruments in 
accordance with the regulations in place. 

 

MANUFACTURER DATA 

The  manufacturer  reserves  the  right  ti  make  future  changes  to  technical  parameters  and  specifica-
tions. 

Product is subject to changes and improvements.

 

Содержание KG 210

Страница 1: ...1 04 2012 User Manual FRIDGE FREEZER KG 210 KG 211 Please read this manual carefully and keep for future reference...

Страница 2: ...st not be dis posed of with the regular household waste The user has to return the product to a collection point for the recycling of electric and electronic equipment The disposal must comply with th...

Страница 3: ...sconnect the appliance quickly in event of an emergency do not use extension cables This device may not be operated by children or persons with physical sensory or mental abilities or lack of experien...

Страница 4: ...h max 20 h Energy consumption 24 h 3 0 49 kWh 0 56 kWh Energy consumption year 3 179 kWh 204 kWh Connection voltage 220 240 V 50 Hz 220 240 V 50 Hz Connection power 140 W 140 W Operating noise 40 dB A...

Страница 5: ...tion with a helper Remove package Lift the appliance away from foamed polystyrene base Tear off adhesive tapes 1 Power green 12 Freezing tablet 2 Thermostat 13 Super Freeze compartment 3 On off switch...

Страница 6: ...tile or combustible materials e g gas fuel alcohol paint etc and in rooms which may have poor air circulation e g garages Only place on a steady and safe surface If the device is not horizontally leve...

Страница 7: ...nners No 8 and No 10 and a Philips head screwdriver When changing the opening direction of the doors YOU CAN NOT lay the refrigerator horizontally Do the actions below in the order they are listed 1 R...

Страница 8: ...ng apertures in the door and put the screw caps in place 14 Place the cover 10 into guides of the bottom cover 1 on the opposite side and attach the cover 1 to its former place STARTUP OPERATION Prior...

Страница 9: ...ion turn the temperature control to the highest setting first until the device has reached the desired operating temperature Afterwards It is recommended to turn the control back to a medium setting c...

Страница 10: ...t with the bottom of the compartment Keep a space between the single items for air circulation Storing frozen food Packed frozen merchandise should be stored in a 4 star freezer compartment in accorda...

Страница 11: ...our properties and spread cold will help to maintain the set temperature in the refrigeration compartment Do not consume ice made in the freezer chamber straight away Products will freeze more quickly...

Страница 12: ...surfaces Regularly clean the hermetic gaskets of the doors Wipe dry Regularly wash the trays and other accessories DO NOT use dishwashing detergent for cleaning trays butter dishes meat compartments...

Страница 13: ...tilation slits install the device freely Loud noise during operation Does the device not stand vertical or hori zontal Adjust the feet accordingly Liquid flow sounds in the cooling circuit are normal...

Страница 14: ...n When being transported the appliance should be protected from atmospheric conditions rain snow dampness The appliance should be firmly secured in place while being transported to avoid slippage or a...

Отзывы: