- 29 -
Electric Connection
WARNING
Danger from electrical current!
Connection to the mains may only be performed by authorized
certified electrician in compliance with the relevant VDE regula-
tions.
► Have the electric connection performed only by an authorized
specialist.
► Before the start of work, disconnect and isolate all poles of the
input line.
Connection Conditions
• Before making the connection, confirm that the power supply conforms to
the information on the name plate on the underside of the appliance.
• The supply line must have an isolating device for all poles with a contact
gap of at least 3 mm in the house installation (fuses, circuit breaker, or
contactor).
• The appliance must be grounded via an earth conductor.
• A rubber-sheathed cable H05VV-F with wire end ferrules and correspond-
ingly rated cross section must be used as the mains connection cable
(EN60335: 5 x 1.5 mm
2
).
• Protection against accidental contact must be guaranteed. For increased
safety, an FI circuit breaker with a trip current of 30 mA should be connect-
ed between the appliance and the mains.
• Connection to a domestic socket (230 V/16 A) and the use of multiple
sockets is not permitted.
• The connection cable must not be bent or clamped.
Mains Connection
The appliance is designed for two connection types (refer to the following fig-
ure):