C H A P T E R 2 - S O F T W A R E
7
Yellow Lightning Alarm
•
The Yellow strike alarm can be enabled or disabled.
•
The
Strike Enable
distance box cannot be set to the same or lower distance than the Red
(or Orange if enabled) strike alarm. The set distance cannot exceed 40 miles or 64km.
•
The
Active For
box sets the duration that the Yellow alarm will remain active when a strike
is detected within the set distance range. The set distance cannot exceed 20 miles/32km
using just the EFM-100 sensor or 40 miles/64km with coincidence mode enabled.
•
The
High Field Enable
box enables/disables a Yellow High Field alarm.
•
The
Above
box is used to set the desired magnitude of the electrical field to activate
the alarm and represents the same positive and negative field levels. This value
cannot be higher than an active Red or Orange high field alarm level.
•
The
Delay On
time is the length of time the set electric field magnitude must
remain above before the alarm is activated. If the electric field magnitude drops
below the set point before the delay expires, the delay timer will be reset. This value
can be set between 1 and 600 seconds.
•
The
Active For
box sets the duration that the Yellow alarm will remain active when
this high field alarm is activated. This value can be set between 1 and 60 minutes.
All Clear Delay Time
•
This timer represents the length of time to wait for no alarm activity until the Green All
Clear status is enabled. If a strike or high field alarm triggers before this expires, the timer
will reset. This value can be set between 1 and 60 minutes.
Содержание ERL-10
Страница 21: ...C H A P T E R 3 O P E R A T I O N 16 Figure 9 ERL 10 Kit 2 with RS 485 Input ...
Страница 23: ...C H A P T E R 3 O P E R A T I O N 18 Figure 11 ERL 10 Kit 2 with Fiber Optic Input ...
Страница 24: ...C H A P T E R 3 O P E R A T I O N 19 Figure 12 ERL 10 Kit 1 with Fiber Optic Input RS485 Output ...
Страница 26: ...C H A P T E R 3 O P E R A T I O N 21 Figure 14 Relay connection example ...
Страница 27: ...C H A P T E R 4 O V E R V I E W 22 Overview Front Panel LEDs Figure 15 ERL 10 Top View Chapter 4 ...