C H A P T E R 1 - S E T U P
3
Setup Instructions
1)
Install EFM-100 (and LD-250 if purchased). Please refer to user manuals of each
detector for installation details.
2)
Connect the EFM-100 Cat6 cable to EPM-1/EFA-21 RJ45 connector.
3)
Connect (optional) DB9 cable from LD-250 to ERL-10 RS232 connector
4)
Connect the USB cable from your computer USB port to the USB connector of
your ERL-10.
5)
Plug in the AC power adapter into the lead of the EPM-1/EFA-21 and into an AC
outlet. The EFM-100, ERL-10 and GSM Dialer will all power up. All of the LEDs
on the ERL-10 will illuminate the indicator lights for 2 seconds then the EFM Data
LED will start blinking. If the fault LED stays on, check EFM-100 power and
connection or refer to Fault Code chart listed in Appendix A
6)
After the ERL-10 is powered up, the USB drivers should automatically install if
there is an active internet connection on the computer. If there is no internet
connection, the USB driver install program can be found on the Boltek USB Flash
Drive in the ERL-10 folder.
7)
Run the ERL-10 program executable on the USB Flash Drive to install the
Configuration, Monitor, and Data Viewer applications.
8)
After installation has completed, run the Config application to set alarm parameters
and click “Write config to ERL
-
10” to save settings to the ERL
-10.
Note:
The GSM-1 only works with the Yellow and Red alarm, the All Clear, and
the Fault relays.
9)
If viewing alarm status on a PC or Laptop, run the Status Monitor software to view
active alarms/all clear status.
Unless changed, once the ERL-10 is powered up, it goes into Survey Mode for a default
time of 20 minutes. If no lightning activity is detected, then the All Clear status light will
illuminate and normal operation of the device will begin.