19
English
3 - Use
I
Option 3: Sensors
Displays the status of the “Rest” sensor and the pressure sensor.
Rest sensor is the sensor checking the position of the main motor.
“ACT” means that the main motor is in the position ready to perform a
cycle. Pressure sensor: the value read by tis sensor is then translated
in the reading of the setting force. At rest, it might be possible that
residual pressure is present < 10 bars
I
Option 4: Push-Pull view
The Push-Pull is calibrated at the factory, this page is giving access
to the sensor status.
I
Option 5: Temperature View
Displays the temperature measured by three internal sensors.
For safety reasons, the machine stops working and displays an
error if an overheating occurs.
I
Option 6: Battery
Displays the type and charge status of the battery. The tool will
stop, in case one of these temperature reach 75°C as a safety rule.
I
Option 7: Next Service
Displays the number of cycles left before the next scheduled service.
A warning will be displayed when approaching and surpassing the
service threshold. The counter is defined for 250 000 cycles, refer
to the shart given on page 27. Reset of this counter can only be
done by Böllhoff staff. Maintenance service frequency is defined for
250 000 cycles.
I
Option 8: Force set. Verify
The menu allows to adjust the convenient conditions for measuring
the real setting force applied on the mandrel using a force indicator
measurement devide (
282 522
14000/00).
An offset < 400 N between measured value and consign appearing
on the display screen is considered as acceptable.
I
Option 9: Restore defaults
This page will allow you to restore the setting as they were at the
initial preparation.)
I
EXIT
For coming back to the “Option” main page.
Call Cardinal Components to Order or for a Quote