PROBLEM
Damaged mandrel threads.
Difficult screwing/unscrewing
actions.
RIVKLE
®
threads
defective after installation.
RIVKLE
®
turns in the hole.
Device does not unscrew
at end of crimping stroke.
Screwing function inoperative.
No crimping stroke.
Tool mandrel spins continuously.
Unscrewing function inoperative
(device blocked on the part).
Tool stuck in the RIVKLE
®
.
PROBABLE CAUSE
1 - Thickness to be crimped
incompatible with RIVKLE
®
.
2 - Excessive crimping stroke.
3 - Device positioning incorrect
during crimping.
4 - Damaged pull-out rod threads.
1 - Damaged mandrel threads.
2 - RIVKLE
®
incompletely screwed
on mandrel.
3 - Excessive crimping stroke.
4 - Thickness to be crimped
incompatible with RIVKLE
®
.
1 - Thickness to be crimped
incompatible with RIVKLE
®
.
2 - RIVKLE
®
head not bearing
on anvil at the time of crimping.
3 - Insufficient crimping stroke.
1 - Low compressed air pressure.
2 - Low oil level.
3 - Motor problem.
1 - No air supply to device.
2 - Push-Pull valve out of adjustment.
1 - Adjustment ring at minimum
position.
2 - Low oil level in tool.
1 - Push-Pull valve out of adjustment.
1 - RIVKLE
®
tapped threads
or mandrel threads damaged.
2 - Low oil level.
3 - Insufficient air pressure.
SOLUTION
1 - Check crimping stroke range
in RIVKLE
®
catalogue.
2 - Repeat crimping test according
to instructions.
3 - Keep mandrel/tool perpendicular
to parent material.
4 - Replace mandrel as per instructions.
1 - Replace mandrel as per instructions.
2 - Adjust anvil position as per
instructions.
3 - Repeat crimping tests as per
instructions.
4 - Check crimping stroke according
to RIVKLE
®
catalogue.
1 - Check crimping stroke according
to RIVKLE
®
catalogue.
2 - Ensure that head is correctly
bearing, when screwing.
3 - Repeat crimping test as per
instructions.
1 - Check air supply pressure.
2 - Fill oil level as per instructions
in § 5.
3 - Check motor rotation at no load.
1 - Check that compressed air
supply to device is ensured.
2 - Adjust Push-Pull valve per
instruction item.
1 - Adjust crimping stroke.
2 - Fill oil level.
1 - Adjust Push-Pull valve per
instruction item.
1 - To release the tool:
- position pin (9) to match an
aperture in nose-piece (5) and
drive pin out,
- unscrew anvil (2),
- release the tool.
2 - Fill oil level as per instructions
in § 5.
3 - Check air pressure.
V - TROUBLESHOOTING AND SOLUTIONS
Before any intervention, check oil level and air supply pressure (between 5.5 and 7 bar)
ENGLISH
8