II - ACCESSORIES
Tooling for RIVKLE
®
item installation with socket head cap screw mandrel
(p. 12)
SOCKET HEAD CAP SCREW CHC DIN912
Screw replacement
- Loosen anvil locknut and unscrew anvil (2)
- Unscrew nose-piece (5)
- Fit screw (1) through washer (3), suitable for the required diameter (no washer for M8)
- Fit drive end piece (4) into screw (1) recess
- Slide the assembly into pull-out bush (7)
- Re-install nose-piece (5)
- Re-install anvil and locknut (2)
STANDARDS TOOLS
Setting tooling for RIVKLE
®
or RIVKLE
®
stud (with special female mandrel)
(p. 12)
If you already use an OPEN tool, the existing female mandrel can be re-used.
Tooling replacement (with special female mandrel)
- Keep nose-piece (5) in place; loosen anvil locknut, then remove anvil (2) and locknut.
- Drive out pin (9) by means of a drift without damaging retaining ring (8)
and release mandrel entirely (1).
- Re-install new mandrel (1) and fit pin (9) again, ensuring that it is retained by retaining ring (8).
- Screw in nose-piece (5) again and torque to 15 Nm.
- Screw in new anvil (2) again inside nose piece and lock by means of locknut.
III - TOOL OPERATION
Anvil position adjustment versus mandrel
- Anvil position depends on RIVKLE
®
length before crimping.
- Adjust anvil position as indicated in figure 3.
- After adjustment, lock anvil locknut (2) to 10 Nm torque..
OPEN RIVKLE
®
BLIND RIVKLE
®
Flush-mounted mandrel at RIVKLE
®
end
Mandrel at 1 turn from thread bottom
3