User Manual
|
【
Instruction acquisition interval (s)
】
Time interval for acquiring instructions, unit: Second.
【
Active address acquisition address
】
Address for actively acquiring tasks.
【
Task result report address
】
Address for reporting task result.
【
Sign verification
】
Sign verification ON/OFF. Default: OFF.
【
Operation mode
】
Offline mode and online mode are optional. Default: Offline mode.
【
HTTP version
】
HTTP version can be modified according to actual need and the device will be restarted after
modification.
After parameter settings, click on
【
Save
】
to validate them.
3.4 Software Upgrade
The software upgrade interface of the access control camera is shown in Pic. 3.4:
Pic. 3.4
【
Upgrade
】
Click on “Browse” to select a correct upgrade file (core file, suffix is .uot) and click on "Upgrade" for
upgrade. Percentage will be displayed in this process and the access control camera will be restarted automatically
after upgrade. Log in to the device again, enter the software upgrade page and check whether core version is the
version upgraded.
Important:
1
、
Please ensure power and network of the access control camera are not cut off in the upgrade process.
2
、
For Windows7 system users, please set up IE parameters according to prompt message below before
upgrade; otherwise, a prompt message that percentage of upgrade will not be displayed normally may
be given. Steps: Open IE browser-tool-Internet option-safety-user-defined level-other-local directory
path is included when file is uploaded to server-enable