User Manual
|
Pic. 3.1.8-3
【
Mask detection
】
Open or Close is optional. It is OFF by default (note: If mask detection is OFF, the mask status on
record is always NO).
【
Temperature correction
】
Intelligent algorithm and low/high temperature algorithm. Under intelligent algorithm
mode, compensation temperature can be set. After that, increase the set compensation temperature after
temperature is measured each time; low/high temperature algorithm means to convert unreasonable body
temperature value into normal body temperature automatically under extreme low or high temperature.
【
Abnormal temperature opens the door
】
Open or Close is optional in case of high temperature alarm. It is Close
by default. If it is set as Open, even high temperature will still opens the door.
【
Temperature threshold
】
Temperature threshold can be set. If temperature exceeds the threshold when contrast
mode includes temperature detection, an alarm will be given. Temperature threshold is 37.3 by default.
【
Temperature unit
】
Celsius or Fahrenheit can be set, when set as Fahrenheit, default temperature threshold will
be changed to 99.1
【
Time period without temperature measurement
】
Specific period of time can be set as the temperature
measurement is not enabled.
3.1.9 Face Recognition• Access Control
Set up related information of access control; Wiegand output control, white light control, same face filtration and
screen display mode can be set;