background image

 

1.5

 

Measuring Instruments, Tools, and Accessories 

While mounting, commissioning, and maintaining the device please use the instruments, tools, 

and accessories shown in Table 1.5.1. 

Table 1.5.1 

Instrument 

Specifications 

Digital multimeter 

AC/DC voltage up to 500V, AC/DC current up to 5A, resistance up 
to 2M Ohm 

Cross slot screwdriver 

2 x 100 mm 

Side-cutting pliers 

160 mm 

1.6

 

Marking and Sealing 

1.6.1

 

Every device has a marking placed on the back side of its closure. 

1.6.2

 

The  marking  contains  the  device  name,  its  decimal  number,  factory  number,  the  year  and 

quarter of production, and conformity marks.  

1.7

 

Packaging 

The device coupled with operation documentation is packaged in a separate cardboard box. 

2

 

Intended Use

 

2.1

 

Operating Restrictions 

The  design  of  the  interface  converter  doesn’t  provide  its  operation  in  aggressive  and  dusty 

environments or in ex-hazardous premises. 

2.2

 

Preparing for Use 

2.2.1

 

Safety Precautions 

 

The design of the interface converter meets the requirements of electric and fire safety 
including emergency operation in accordance with Russian standards GOST 12.2.007.0-75 and 
GOST 12.1.004-91; 

 

There are no potential hazard circuits within the device; 

 

Do SHUT OFF power from the device before mounting, installing, and maintaining this one; 

 

Mounting and maintenance of the USB-RS232 shall be carried out by persons with the second 
or higher accident prevention level. 

2.2.2

 

Design 

The  view  and  overall  dimensions  of  the  USB-RS232  interface  converter  are  presented  in 

Figure 2.1. 

 

Figure 2.1

 Overall Dimensions of USB-RS232 

2.2.3

 

Mounting 

The  interface  converter  shall  be  operated  at  locations  protected  against  atmospheric 

precipitations and mechanical damage. 

No…………….. 

Содержание USB-RS232

Страница 1: ...INTERFACE CONVERTER USB RS232 USER S MANUAL ...

Страница 2: ...ns 6 2 2 Preparing for Use 6 2 2 1 Safety Precautions 6 2 2 2 Design 6 2 2 3 Mounting 6 2 2 4 Connecting to the PC 7 2 2 5 Testing Operability 8 2 2 6 Extreme Situation Actions 9 3 Maintenance 9 3 1 General 9 3 2 Safety Precautions 9 3 3 Maintenance Procedures 9 3 4 Performance Testing 9 3 5 Technical Examination 9 3 6 Preservation Depreservation Represervation 9 4 Repair 9 5 Storage 10 6 Transpor...

Страница 3: ...rface Converter Only the personnel who have studied this manual are allowed to operation activities All activities on mounting programming and commissioning shall be performed in compliance with the requirements of the regulatory documentation in force at the place of operation ...

Страница 4: ... a PC 1 2 2 Consumed current mA 200 max 1 2 3 Baud Rates bit s 110 300 1200 2400 4800 9600 19200 38400 57600 115200 1 2 4 Operating temperature range С Minus 30 to 50 1 2 5 Relative humidity Up to 95 at 40 С 1 2 6 RFI caused by the equipment as per GOST R 50009 2000 Not exceed 1 2 7 Weight gram 11 1 2 8 Overall dimensions mm 19 67 11 max 1 2 9 Enclosure protection degree IP20 1 2 10 Non stop opera...

Страница 5: ...s The design of the interface converter doesn t provide its operation in aggressive and dusty environments or in ex hazardous premises 2 2 Preparing for Use 2 2 1 Safety Precautions The design of the interface converter meets the requirements of electric and fire safety including emergency operation in accordance with Russian standards GOST 12 2 007 0 75 and GOST 12 1 004 91 There are no potential...

Страница 6: ...hould install its driver can be found at the company site http bolid ru in the section PRODUCTS on the page of the USB RS232 interface converter Unpack CP210x_VCP_Windows zip and run the driver installation file that relates to the current operating system bitness CP210xVCPInstaller_x86 exe for a 32 bit system or CP210xVCPInstaller_x64 exe for a 64 bit system The Installer window appearing click N...

Страница 7: ...on and device being ready for operation Upon installation of the interface converter driver the group Ports COM LPT of the Device Manager shall contain the entry CP2104 USB to UART Bridge COM x where x is the number of the virtual COM port 2 2 4 5 After the necessary connections are carries out connect the interface converter to the RS232 interface bus via the removable terminal block 2 2 5 Testin...

Страница 8: ...nt 3 6 Preservation Depreservation Represervation Preservation is not applicable for this equipment 4 Repair 4 1 Repair of faulty equipment is to be conducted by the manufacturer or in authorized repair centers The equipment shall be sent for repair in line with established procedures 4 2 An equipment fault resulted from consumer s not observing rules of mounting and operation is not a reason for ...

Страница 9: ...rements stated in the manuals if the user follows the instructions for transportation storage installation and usage 8 2 The warranty period is 18 months since putting the product into operation but no more than 24 months from the manufacturer s date of production 9 Certification Information 9 1 The USB RS232 interface converter meets the requirements of the Technical Regulations TR CU 020 2011 an...

Отзывы: