16
7.
Quitting the mode of programming the Master Key is performed by short closing the reader
contacts for 4 seconds or automatically in 30 seconds after completing configuring operation.
In this case the panel issues one beep and then one long sound signal. Quitting can also be
performed by shutting the power off.
Programming credentials for arming and disarming alarm loops without using a PC:
1.
Disarm all the alarm loops with the types Intrusion and Entrance.
2.
Enter the mode of programming credentials by touching the UO-4S reader by the Master Key;
the UO-4S shall issue the signal of proceeding to the programming mode (three pairs of
double beeps).
3.
Briefly touch the UO-4S reader by another iButton. The iButton code shall be entitled in the
UO-4S memory and the beeper beeps twice.
4.
Light indicators LP1÷LP4 show the number of programmed credential in binary code (see
Table 6) and then after two seconds they show the states of the related alarm loops.
Notes:
–
If the credential code has already been in the panel memory then the beeper issues a short
Confirmation sound.
–
If the credential memory is full (16 credentials has already been enrolled) then the beeper
issues a long Error signal.
5.
Define the match between the credential and the alarm loop(s) by brief closing of the relevant
alarm loop. If the LED related to the alarm loop illuminates it means that the alarm loop can be
operated by this credential.
6.
To confirm programming, briefly touch the UO-4S readers by the same credential. The credential
authorized to arm and disarm will be saved in the device memory.
7.
To program the panel for using other credentials, repeat steps 3–5.
8.
To quit the mode of programming credentials, close the reader terminals for 4 seconds, or the
panel quits this mode automatically in 30 seconds after last operation. The beeper beeps once.
Quitting can also be performed by shutting the power off.
Table 6. Indicating User Number by Alarm Loop LEDs
#
LP1
LP2
LP3
LP4
#
LP1
LP2
LP3
LP4
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
Deleting Arming / Disarming Credentials
1.
Disarm all the Entrance and Intrusion alarm loops.
2.
Enter the mode of programming credentials by touching the UO-4S reader by the Master Key. The
panel shall issue the signal of proceeding to the programming mode (three pairs of double beeps).