©2008 Heatcraft Refrigeration Products LLC
Nomenclature
lt
A
053
B
A
Model Series
Model type
Capacity
Electrical Code
design revision
Bohn Extended Thin
Profile Unit Cooler
A = Air defrost
L = Electric defrost
# BTUH x 100
A = 115/1/60
B = 208-230/1/60
Features & Benefits
Cabinet
Low height makes it the most compact unit for reach-in display cases where space is limited, giving the case a clean look
and allowing for more shelving and product storage
Textured aluminum cabinet
Easy access to motors and the refrigerant and electrical components with front access panel
Modular front access panels provide easy access to motors and can be removed independently of the drain pan
Plastic vibration isolators for fan panels and drain pan reduce noise and vibration
Liquid-line solenoid wire harness comes standard for quick installation
•
•
•
•
•
•
Coil
Internally enhanced tube design produces better unit performance
Blow-through coil means air is discharged through the coil
Heaters are attached to the coil for easier serviceability
Models available for R-404A and R-22 refrigerant
•
•
•
•
Controls
Defrost termination control
Fan delay control
Heater safety control
•
•
•
options
Reverse air flow
Beacon II™ compatible
Smooth white painted cabinet
Pre-assembled units with factory mounted TXV, liquid-line solenoid and room thermostat
Coated coil for corrosion protection
•
•
•
•
•
Nomenclature ..........................................................................................................................................................................................................2
Features & Benefits ................................................................................................................................................................................................2
Performance Data & Specifications
Air Defrost .........................................................................................................................................................................................................3
Electric Defrost ................................................................................................................................................................................................3
Physical Data ............................................................................................................................................................................................................3
Dimensional Data ...................................................................................................................................................................................................3
Table of Contents