©2008 Heatcraft Refrigeration Products LLC

Nomenclature

lt

A

053

B

A

Model Series

Model type

Capacity

Electrical Code

design revision

Bohn Extended Thin 

Profile Unit Cooler

A = Air defrost

L = Electric defrost

# BTUH x 100

A = 115/1/60   

B = 208-230/1/60 

Features & Benefits

Cabinet

Low height makes it the most compact unit for reach-in display cases where space is limited, giving the case a clean look 

and allowing for more shelving and product storage 

Textured aluminum cabinet

Easy access to motors and the refrigerant and electrical components with front access panel

Modular front access panels provide easy access to motors and can be removed independently of the drain pan

Plastic vibration isolators for fan panels and drain pan reduce noise and vibration

Liquid-line solenoid wire harness comes standard for quick installation

Coil

Internally enhanced tube design produces better unit performance

Blow-through coil means air is discharged through the coil

Heaters are attached to the coil for easier serviceability

Models available for R-404A and R-22 refrigerant

Controls

Defrost termination control

Fan delay control

Heater safety control

options

Reverse air flow

Beacon II™ compatible

Smooth white painted cabinet

Pre-assembled units with factory mounted TXV, liquid-line solenoid and room thermostat

Coated coil for corrosion protection

Nomenclature ..........................................................................................................................................................................................................2

Features & Benefits ................................................................................................................................................................................................2

Performance Data & Specifications

Air Defrost .........................................................................................................................................................................................................3

Electric Defrost ................................................................................................................................................................................................3

Physical Data ............................................................................................................................................................................................................3

Dimensional Data ...................................................................................................................................................................................................3

Table of Contents