background image

fore the brake section, and a stop section (or a transition track section alternatively) after the 
brake section.

The Bogobit Standard-Bremsmodul has the following features:

1. The brake module can be connected in parallel to a turnout or a signal (with double 

solenoid drive).

2. In the proceed state, full digital voltage is applied to all track sections. (no jerky drive on 

the transition track).

3. The control inputs can be driven universally by AC or DC voltage of either polarity.

5 Connection and Operation

5.1 Handling

The product consists of sensitive electronic components. Improper handling may destroy them. 
Prior to handling the board, please discharge yourself from electrostatic charge. To do this, touch a 
metal object (earthed), e.g. a metal PC casing. Try to touch the board only at the edges and avoid 
touching any electronic components or copper routes on the board.

5.2 Mounting

Mount the module properly to the model railway framework. The module has holes with 3 mm 
diameter for mounting. Use of wood screws with 3 mm diameter and a flat pan head is recommen-
ded. Use spacers (little plastic tubes) between circuit board and mounting surface. Tighten the 
screws carefully, so that the circuit board does not warp. Also consider the instructions related to 
heat generation in chapter 3.3.

5.3 Electrical Connections 

5.3.1 Wiring Terminals

The external connections of the brake module are labelled on the board and explained in the table 
below:

Label

Meaning

Connection

0

0

to digital control station "0" / track rails

B

B

to digital control station "B" / track center studs

Ü#

transition track

to center studs of the isolated transition track section

B#

brake track

to center studs of the isolated brake track section

S*

switch contact common if stop section required: connect to "B"

SG

switch contact green

if stop section required: connect to center studs of stop section

SR

switch contact red

if stop section required: no connection

R*

relay common

to turnout decoder, yellow wire connection

bogobit Standard-Bremsmodul · 2016-08-01

Seite 4 / 7

Содержание Standard-Bremsmodul

Страница 1: ...Bogobit Standard Bremsmodul Manual bogobit Standard Bremsmodul 2016 08 01 Seite 1 7...

Страница 2: ...to property or personal injury caused by improper use or the failure to observe the safety instructions The warranty is voided in these cases For safety and licensing reasons CE it is not permitted to...

Страница 3: ...sic is a brake module for digitally controlled model railways The module generates a brake voltage This brake voltage when applied to the track lets locos brake smoothly if they are equipped with a su...

Страница 4: ...e model railway framework The module has holes with 3 mm diameter for mounting Use of wood screws with 3 mm diameter and a flat pan head is recommen ded Use spacers little plastic tubes between circui...

Страница 5: ...top section it has a length so that every loco comes to a halt reliably Connect the center studs of this section to SG and connect S with B A stop section is recommended if you cannot be sure that any...

Страница 6: ...t is sufficient to apply the control voltage only for a very short time 20 ms A per manently applied control voltage is acceptable but will lead to a certain rise of temperature in the relay For a per...

Страница 7: ...ance with legal regulations 8 3 Address of Manufacturer For technical enquiries please contact bogobit Siegfried Grob Burgstr 8 89192 Rammingen Germany E Mail anfrage bogobit de 9 References The follo...

Отзывы: