The intercom system shall be a Bogen Model PI35A.
The PI35A shall provide instantaneous intercommuni-
cation and background music (or other program) for
up to 25 speaker-equipped stations. A 20-watt inter-
com amplifier shall feature a frequency response that
has been shaped for maximum intelligibility. A built-in
35-watt program amplifier shall ensure that program
material and/or emergency announcements are clear-
ly heard and easily understood. The front panel shall
include step-by-step instructions and color-coded
guidelines for easy access and operation.
Complete facilities shall be provided for distributing
program material from microphones, CD player, or
other background music source. Distribution shall be
accomplished by simple push-button selection, follow-
ing color-coded guidelines. Emergency announce-
ments shall take precedence over program distribu-
tion and shall be accomplished with a single push-but-
ton selection and a built-in console microphone.
Provision shall be included to permit the distribution
of a time signal to all stations.
Optional paging facilities shall permit emergency all-
call paging from a remote telephone or microphone.
Telephone paging captures system priority and over-
rides all system functions except the emergency
page feature.
The PI35A shall include a built-in time tone that can
be sent to the entire system, supervisory tone to sig-
nal unauthorized monitoring from the control panel,
and monitor speaker to monitor a program or listen
to a station.
A room selector panel shall be provided to select
intercom and program functions for each station. Calls
from stations shall be initiated through call-in switch-
es and shall be announced at the control center by
light and tone annunciation. Provisions shall be made
for two-wire hook-up or voice call-in wiring.
The PI35A shall be enclosed in a space-saving console,
finished in an attractive simulated wood grain finish.
The system shall provide a 25-volt balanced output
and operate from a
1
20V AC, 60 Hz source. Maximum
power consumption shall be
1
00 watts. Dimensions
shall be 20-
1
/2" W x 8-
1
/2" H x
11
" D. Shipping weight
shall be 29 lb.
Technical
Specifications
50 Spring Street, Ramsey, NJ 07446, U.S.A.
Tel. 20
1
-934-8500; FAX: 20
1
-934-9832; www.bogen.com
Rated Output:
Program –
35WRMS
Intercom –
20WRMS
Frequency Response:
Program –
+
1
, -3 dB from 80 Hz to
1
5 kHz
Intercom –
Shaped for maximum intelligibility
Distortion
: Less
than
1
% at rated power and bandwidth
Inputs:
Two Lo-Z balanced MIC: Hi-Z unbalanced AUX; Telco Page; 25V Booster
Output:
25V Balanced line, Line Out to Booster
Input Sensitivity:
Program –
MIC Input: 300µV balanced Lo-Z; AUX:
1
00mV unbalanced Hi-Z
(for rated output)
Telco Page:
1
00mV unbalanced Hi-Z;
Intercom –
Listen Mode: 300µV
balanced Lo-Z (Console MIC:
1
mV unbalanced Lo-Z)
Controls:
Front Panel –
Program Selection: MIC
1
, MIC 2, AUX; Level: Monitor/
Listen, Program; Distribution: All Rooms, Emergency, Press To Talk;
Indicators: Program Talk/ Level LED
Rear Panel –
Input Gain: MIC
1
, MIC 2, AUX, Telco Page, Talk, Listen
Internal –
Gain: Emergency Page, Supervisory Tone, Time Tone
Enable/Disable: MIC
1
/Console MIC; MIC 2/Telco Page, Phantom Power,
Supervisory Tone, MIC
1
/Monitor Mute
Tone Specifications:
Time Tone –
750 Hz
Supervisory Tone –
Repeating, 500 Hz
Call-in Tone –
Repeating; oscillates between 500 Hz and 750 Hz (Switching Freq.,
1
6 Hz)
Power Requirements:
1
20V AC, 60 Hz,
1
00W maximum
Dimensions:
20-
1
/2" W x 8-
1
/2" H x
11"
D (with sloped top)
Cabinet:
Simulated wood grain finish
Panels:
Black with color-coded lines and instructions for Intercom, Program, Emergency Page
Shipping Weight:
29 lb.
Operating Temp.:
0-
1
30° F
Accessory Equipment:
CDR
1
– CD player and AM/FM Receiver
SCR25A – Call-in module (for switches w/o SCR)
WMT
1
A – Line-matching transformer for telephone paging
TAMB – Telephone access module for telephone paging
DDU250, MBS
1
000A – Desktop paging microphones
CA
1
0A, CA
11
A, CA
1
7 – Call-in switches (2-pos., 3-pos., and push-button, respectively)
TWK35
1
– 2-Wire call-in adapter kit
25
1
8, 2520, 2522 – Connector Kits (
1
8-, 20-, and 22-gauge respectively)
TL
1
56 – Insertion Tool for connector kits
Architect
and Engineer
Specifications