2. A minimum of three paging zones and maximum zone capac-
ity of ninety-nine (99) paging zones. The system shall be
expandable in groups of three zones.
3. Up to 32 field-programmable paging zone groups, each con-
sisting of
1
to 99 zones.
4. Field programmable Night Ringer Zone Group, consisting of
from
1
to 99 zones. This feature shall be activated by high-
voltage ring signal or contact closure.
5. Field programmable Emergency/Shift change Zone Group,
consisting of from
1
to 99 zones. This feature shall require
activation by a customer-supplied contact closure, and sound
a user-selected tone. The user shall have the choice of no
tone (allowing use of outside tone source), tone burst (
1
-7
sec. duration, user-selected), single chime, or quad beep.
6. Emergency All-Facility Page Override. This feature shall be
activated through a loop start trunk or through contact clo-
sure and dry audio input. It shall override the normal paging
features of the system, sound a user-defeatable alert tone in
all zones, and open an audio channel for a voice page.
7. Built-in, talkback amplification of central-amplified zones.
This feature shall require the addition of the PCMTBM mod-
ule.
8. Background music assigned per zone and local background
music sourcing capability.
9. Field programmable Code Call Zone Group, consisting of
from
1
to 99 zones.The user shall have the choice of pattern
or echo code calls, and repeat functions.
1
0. Eight daily time-triggered signaling events. This feature
requires the use of the PCMTBM module.
11
. Two (2) C-form relay contact sets for activating external
equipment. The contacts shall change state when the unit is
activated.
1
2. Capability of providing uninterrupted background music to
all zones not being paged.
1
3. Non-volatile RAM shall be included to allow for retention of
programming information during power interruptions
1
4. Screwdriver-adjustable volume control of confirmation, pre-
announce, error, and shift change/emergency-call tones.
50 Spring Street, Ramsey, NJ 07446
20
1
-934-8500 FAX: 20
1
-934-9832 www.bogen.com
Architect & Engineer Specifications, cont.