Architect & Engineer Specifications*
The zone paging system shall be the Bogen PCM2000 Zone
Paging System, designed for direct connection to loop start and
ground start trunks, to PBX or KEY paging ports which supply
DTMF capability, and to analog T/R lines. The unit shall allow
total system amplifier power of up to 250W.
The unit shall include flanges with keyhole slots for wall-mount-
ed installation. Operation shall require a
1
2V (
1
.5A) DC power
supply. A suitable power supply shall be provided (PCMPS2
power supply).
The system shall consist of the appropriate modules as speci-
fied and shall be registered under Part 68 of FCC rules.
Modules
All modules shall be designed for wall-mounted installation.All
modules shall be equipped with a ribbon cable and connector
and power cable with connector to permit them to be inter-
connected to each other.The face plates of each module shall
be finished in black, with each control/connector clearly labeled
in white. Each face plate shall have knockouts to facilitate cable
and wire dressing. All connections shall be made using a small
regular screwdriver or common jacks (RJ
11
or RCA).
The following modules shall be available:
PCMTIM
- Telephone Interface Module. One PCMTIM mod-
ule shall be provided per PCM2000 system. The module shall
provide for telephone interface selection via built-in DIP
switches. It shall include a volume control for tone and BGM
source, and RJ
11
jacks for night ringer, telephone line, and over-
ride.A connector block, using screw terminal connections, shall
be provided for BGM source, and two (2) C-form relay contact
sets. A power-on LED indicator shall be provided to indicate
power-applied status.
PCMCPU
- Central Processing Module. One PCMCPU mod-
ule shall be provided for the first nine (9) zones in the system.
One PCMCPU module shall be needed for each satellite sys-
tem.
The module shall provide for satellite system identification via
built-in DIP switches. It shall include a locking program/run
selector switch (with program LED), satellite data link RCA
jack, and
1
2V DC power source jack.A connector block, using
screw terminal connections, shall be provided for paging ampli-
fication connection, low-power and high-power BGM connec-
tions, emergency/shift change signal activation, AUX contact
closure, and
1
2V DC power source connection. A power-on
LED indicator shall be provided to indicate power-applied sta-
tus.
PCMZPM
- Zone Paging Module. One PCMZPM module shall
be provided for each three (3) paging zones in the system. Up
to three (3) PCMZPM modules may be connected to the mas-
ter system, for a total zone capacity of 9 zones. Up to three (3)
additional PCMZPM modules may be connected with a PCM-
CPU module to form a satellite system to further increase
zone capacity.
The PCMZPM module shall provide built-in DIP switches to set
talkback on/off for each zone. It shall include a power-on LED,
low-power background music volume control, background
music out/in jumper field, local BGM selection jumpers, and
high-power/low-power operation selector switch.A connector
block, using screw terminal connections, shall be included to
connect local background music, zone wiring, and relay driver
outputs.
PCMTBM
- Talkback Module. One PCMTBM talkback module
shall be provided per system (including any satellite systems).
The module shall provide for talkback operation in centrally-
amplified zones (only). The module shall provide a power-on
LED, talkback volume control, and talkback switching delay con-
trol. A connector block, using screw terminal connectors shall
be included for paging amplification wiring.
The PCM Zone Paging System shall supply the following fea-
tures and functions:
1
. Simultaneous high-power and low-power paging.Total sys-
tem high-power audio capacity of 250W.