33
To view status for the power amplifier:
Step 1
On the appliance Web UI’s main page, select
DSP
.
Step 2
Select the
Menu
button for the channel.
From the drop-down menu, select
Status
.
The view only information that appears is described in the following
table:
Table 13, Status
Switch Position
Indicates the position of the Amplifier Mode
switch located on the rear of the appliance.
Bridged mode is typically used when higher
power, single channel operation with a high
impedance loudspeaker load is needed. For
information about setting the Amplifier
Mode, refer to the installation manual for the
appliance.
Thermal Protect
Appears red if the equipment has become
too hot and has placed itself into protection
mode. Otherwise, the LED is green.
Channel 1 Output
Limit
Appears red if the output signal is being
clipped or distorted. Otherwise, the LED is
green.
Channel 2 Output
Limit
Appears red if the output signal is being
clipped or distorted. Otherwise, the LED is
green.
Temperature
Provides the real-time temperature of the
appliance in both Celsius and Fahrenheit.
Содержание NYQUIST NQ-A4060