TWK351 Option

The TWK351 option permits light call-in on 2-conductor shielded cable.
See Figure 7 for wiring diagram. 

Staff Station Equipment

Staff station equipment may include wall-or ceiling-mounted cone loud-
speakers, or horn-type loudspeakers (used to ensure clear, intelligible
communication in areas with relatively high noise levels). Figure 9 shows
a wiring diagram for a loudspeaker. To initiate calls, locations are provided
with call-origination switches. The voice call-in option may be used when
stations are equipped with a customer-supplied DPDT momentary switch.

Call-Origination Switches

Voice Call-In Option

– A customer-supplied double-pole, double throw,

momentary contact switch maybe used to connect a staff station speaker
to the call-in line when the switch is actuated. See Figure 8.

CA10A and CA11A

– These momentary, rocker-type Call Switches are

used to signal the control panel operator to establish communications
through a two-way speaker. The CA11A incorporates a privacy mode to
prevent monitoring. See Figure 10.

Appendix

General Wiring

Where possible, locate the MCP35A centrally, relative to the rooms being
served, in order to minimize the length of speaker cables. Orient the unit
so that the operator, program director, or other parties are able to see the
controls at all times. Provide adequate lighting and ventilation. Do not
locate the unit close to heat sources (radiators, warm air ducts, etc.), or a
wall which would impede air flow through or around it.

Wires

– Class II wiring may be used for all audio and annunciator lines.

Support cables to prevent sagging or strain. Keep wires clear of objects
that would subject them to heat, friction, or other abuse.

Use No. 22 AWG shielded pairs with insulated outer jacket for speaker lines.
Annunciator lines require a third wire, which usually is No. 22AWG insu-
lated wire with clear insulation. The number and type of wire running from
each room to the control center are dependent upon the type of speaker
operation required. See Table 1.

Figure 7 – Wiring Diagram: TWK351 Option

Figure 9 – Wiring Diagram: Loudspeaker (only)

Figure 8 – Wiring Diagram: Room Speaker with

Customer-Supplied Voice Call-In Switch

Figure 10 – Wiring Diagram:   A: Model CA10A; B: Model CA11A

A.

B.

Содержание MCP35A

Страница 1: ...Specifications subject to change without notice 2010 Bogen Communications Inc All rights reserved 54 5871 03E 1004 MCP35A Master Control Panel Installation Use Manual ...

Страница 2: ... produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Prote...

Страница 3: ...anel 5 External MIC for MIC 1 Console MIC Rear Panel 5 Time Tone Rear Panel 5 External Booster Amplifier Rear Panel 5 Remote Emergency Telephone Paging Rear Panel 5 Remote Emergency Microphone Paging Rear Panel 5 Associated Equipment 6 7 SBA225 Room Selector Panel 6 SBA225 Wiring 6 SCR25A Call In Module 6 SCR25A Installation 6 TWK351 Option 7 Staff Station Equipment 7 Call Origination Switches 7 A...

Страница 4: ...itches and can include privacy control to positively pre vent monitoring Provision is included for voice call in from stations equipped with voice call in switches The MCP35A control panel permits the user to Establish direct two way communication between the control panel and any speaker equipped location via a room selector panel and the press to talk release to listen push button while maintain...

Страница 5: ...o a station via the INTERCOM channel 3 2 6 7 3 4 5 9 11 8 1 Front Panel Rear Panel 1 Microphone Inputs A terminal strip provides connection for two low im pedance balanced microphones May optionally provide phantom power The console microphone is used as MIC 1 however this feature may be disabled Use two conductor shielded microphone cable 2 Voice Call In Connects parallel lines from station call ...

Страница 6: ...id electric shock be sure to disconnect AC Power Cord before removing the cover of the amplifier unit Warning DO NOT perform any function requiring the removal of the cover of the unit unless you are qualified to do so Gain Adjustments Internal Internal controls are provided to set the level of emergency page volume privacy tone volume and time tone volume These controls are factory set under norm...

Страница 7: ...d to the MIC 1 input see Fig 2 Time Tone Rear Panel A tone signal sounds through all speakers when the time clock terminal is grounded through a closure The tone may be used as a class change sig nal or for other purposes such as a telephone night ringer or alarm signal External Booster Amplifier Rear Panel Model BPA60 provides increased power output To install connect a cable terminated in a male...

Страница 8: ... using one female centerline plug to terminate wires from the speaker and or call switch Connect the shield to the ground terminal This is the only place where speaker cable shields should be grounded SCR25A Call In Module Caution The installation of accessory equipment requires the removal of protective covers exposure of internal components presents an electrical shock hazard Accessory equipment...

Страница 9: ...t monitoring See Figure 10 Appendix General Wiring Where possible locate the MCP35A centrally relative to the rooms being served in order to minimize the length of speaker cables Orient the unit so that the operator program director or other parties are able to see the controls at all times Provide adequate lighting and ventilation Do not locate the unit close to heat sources radiators warm air du...

Страница 10: ... are connected by a common control cable and one cable is run to the control panel If this type of installation is not practical the control cables for two or more switches are run to the control center and are connected in parallel at a junction box a single control cable is then run to the terminal strip at the rear of the MCP35A chassis Call Privacy Option Figure 10 shows the room connections a...

Страница 11: ...9 Figure 11 Schematic Diagram SBA225 Room Selector Panel Figure 12 Typical Interconnection Diagram Figure 13 Typical Wiring Diagram ...

Страница 12: ...een subjected to abuse misuse improper storage neglect accident improper installation or have been modified or repaired or altered in any manner whatsoever or where the serial number or date code has been removed or defaced THE FOREGOING LIMITED WARRANTY IS BOGENʼS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERʼS SOLE AND EXCLUSIVE REMEDY BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND EITHER EXPRESS O...

Отзывы: