Bogen LMR1S Скачать руководство пользователя страница 3

2

5

WARNING:

Turn off power to unit and make all jumper
selections before installing module in unit.

Jumper Selections

Priority Level

*

This module can respond to 4 dif-
ferent levels of priority. Priority 

1

is the highest priority. It mutes
modules with lower priorities and
is never muted. Priority 2 can be
muted by Priority 

1

modules and

can mute modules set for Priority
Level 3 or 4. Priority 3 can be
muted by either Priority 

1

or 2

modules and can mute Priority 4
modules. Priority 4 modules are
muted by all higher priority mod-
ules. Remove all jumpers for “no
mute” setting.

*

The number of priority levels avail-

able is determined by the equipment
the modules are used in.

LINE   MIC

PHANTOM

PWR

GATING

ENABLE 

BUS

ASSIGNMENT

PRIORITIES

J11

J2

J10

J12

J13

J4

MIC/LINE

SWITCH

LINE LEVEL INPUT

MIC LEVEL INPUT

ON

OFF

PHANTOM

POWER

ENABLED

DISABLED

GATING

A

BUS ASSIGNMENT

B

BOTH

PRIORITY LEVELS

1

2

3

4

HIGHEST

LOWEST

Gating

Gating (turning off) of the modules output when insufficient audio is present at the input can
be disabled. Detection of audio for the purpose of muting lower priority modules is always
active regardless of this jumper setting.

Phantom Power

24V Phantom power can be supplied to condensor microphones when jumper is set to ON
position. Leave OFF for dynamic mics.

Bus Assignment

This module can be set to operate so that the mono signal can be sent to the main unit’s
A bus, B bus, or both buses.

MIC/LINE Switch

Sets input gain range for the intended input device. MIC gain range 18 – 60 dB, LINE gain
range -2 – 40 dB.

Remote Control

These configurations use the included wall-mounted remote panel. Up to 2,000 feet of #24
wire can be run from the remote panel to the LMR

1

S.

Single Conductor Shieldes Remote Connections

The maximum wire run length for this configuration is 200 feet. Use one-conductor shielded
wire for this configuration.

REMOTE

REMOTE

CONTROL

CONTROL

cs+

WIPER

SHIELD

SHIELD

SHIELD

cs+

WIPER

GND

LMR1S Remote Panel

LMR1S Remote Panel

1

2

3

REMOTE

REMOTE

CONTROL

CONTROL

JUMPER FROM CS+

TO WIPER TERMINAL

SHIELD

SHIELD

cs+

WIPER

GND

1

2

3

LMR1S Remote Panel

LMR1S Remote Panel

Two-Conductor Shielded Remote Connections

This configuration is recommended when wire runs up to 2,000 feet are necessary. Use two-
conductor shielded wire for this connection.

Note:

If no connections are made to the remote control, the LMR

1

S module defaults to 0 dB of

attenuation.

Note:

If no connections are made to the remote control, the LMR

1

S module defaults to 0 dB of

attenuation.

Содержание LMR1S

Страница 1: ...ut Electronically balanced input Gain Trim control with Gain range switch Bass and treble 24V Phantom power Audio Gating Gating with threshold and duration adjustments Built in limiter with LED activity indicator Fade back from mute 4 levels of available priority Can be muted from higher priority modules Can mute lower priority modules Screw terminal input 2007 Bogen Communications Inc 54 2158 01A...

Страница 2: ......

Страница 3: ...ANTOM PWR GATING ENABLE BUS ASSIGNMENT PRIORITIES J11 J2 J10 J12 J13 J4 MIC LINE SWITCH LINE LEVEL INPUT MIC LEVEL INPUT ON OFF PHANTOM POWER ENABLED DISABLED GATING A BUS ASSIGNMENT B BOTH PRIORITY LEVELS 1 2 3 4 HIGHEST LOWEST Gating Gating turning off of the modules output when insufficient audio is present at the input can be disabled Detection of audio for the purpose of muting lower priority...

Страница 4: ...ly he s the of ...

Страница 5: ...R1S The attenuation level is linear with voltage 4 5V or greater 0 dB of attenuation full volume and 0V 80 dB of attenuation Distance from the source should be kept to 200 feet or less The CS terminal is not used in this configuration IMPORTANT Maximum voltage input should be limited to 10V SHIELD VOLTAGE SOURCE 0 5V REMOTE REMOTE CONTROL CONTROL 1 2 3 Note If no connections are made to the remote...

Страница 6: ...MENT BOTH EST n N ...

Страница 7: ...uses can o 40 6 ates lim sig oun ter Block Diagram CS W GND INPUT ATTEN _ GND MIC LINE INPUT MIC LINE ...

Страница 8: ...ut notice ...

Отзывы: