2
5
WARNING:
Turn off power to unit and make all jumper
selections before installing module in unit.
Jumper Selections
Priority Level
*
This module can respond to 4 dif-
ferent levels of priority. Priority
1
is the highest priority. It mutes
modules with lower priorities and
is never muted. Priority 2 can be
muted by Priority
1
modules and
can mute modules set for Priority
Level 3 or 4. Priority 3 can be
muted by either Priority
1
or 2
modules and can mute Priority 4
modules. Priority 4 modules are
muted by all higher priority mod-
ules. Remove all jumpers for “no
mute” setting.
*
The number of priority levels avail-
able is determined by the equipment
the modules are used in.
LINE MIC
PHANTOM
PWR
GATING
ENABLE
BUS
ASSIGNMENT
PRIORITIES
J11
J2
J10
J12
J13
J4
MIC/LINE
SWITCH
LINE LEVEL INPUT
MIC LEVEL INPUT
ON
OFF
PHANTOM
POWER
ENABLED
DISABLED
GATING
A
BUS ASSIGNMENT
B
BOTH
PRIORITY LEVELS
1
2
3
4
HIGHEST
LOWEST
Gating
Gating (turning off) of the modules output when insufficient audio is present at the input can
be disabled. Detection of audio for the purpose of muting lower priority modules is always
active regardless of this jumper setting.
Phantom Power
24V Phantom power can be supplied to condensor microphones when jumper is set to ON
position. Leave OFF for dynamic mics.
Bus Assignment
This module can be set to operate so that the mono signal can be sent to the main unit’s
A bus, B bus, or both buses.
MIC/LINE Switch
Sets input gain range for the intended input device. MIC gain range 18 – 60 dB, LINE gain
range -2 – 40 dB.
Remote Control
These configurations use the included wall-mounted remote panel. Up to 2,000 feet of #24
wire can be run from the remote panel to the LMR
1
S.
Single Conductor Shieldes Remote Connections
The maximum wire run length for this configuration is 200 feet. Use one-conductor shielded
wire for this configuration.
REMOTE
REMOTE
CONTROL
CONTROL
cs+
WIPER
SHIELD
SHIELD
SHIELD
cs+
WIPER
GND
LMR1S Remote Panel
LMR1S Remote Panel
1
2
3
REMOTE
REMOTE
CONTROL
CONTROL
JUMPER FROM CS+
TO WIPER TERMINAL
SHIELD
SHIELD
cs+
WIPER
GND
1
2
3
LMR1S Remote Panel
LMR1S Remote Panel
Two-Conductor Shielded Remote Connections
This configuration is recommended when wire runs up to 2,000 feet are necessary. Use two-
conductor shielded wire for this connection.
Note:
If no connections are made to the remote control, the LMR
1
S module defaults to 0 dB of
attenuation.
Note:
If no connections are made to the remote control, the LMR
1
S module defaults to 0 dB of
attenuation.