background image

1

. TEL Line Connector - 

Analog station line connection (Tip and Ring) is made via

an RJ

11

connector that is pre-wired to a 2-position pluggable terminal block. The

connections to the terminal block are not polarity sensitive. (See 

Wiring, pg.

5.)

2. Speaker Volume POT - 

The Speaker Volume POT controls the speaker volume

level of the unit. Clockwise rotation (looking at POT) increases the volume.

3. Microphone Level POT -

The Microphone Level POT adjusts the microphone

return talk level of the unit. In certain noisy locations (e.g., background traffic,
machinery, or wind) the microphone threshold level may need to be decreased, oth-
erwise the unit might detect the background noise as valid audio thereby causing the
unit to remain in the talk mode. Clockwise rotation (looking at POT) increases the
return talk level.

4. Noise Reduction - 

Slowly mutes the level to the phone when only

background noise, not active audio, is detected.

5. Active LED - 

For use when installing and troubleshooting, the LED indicates that

the unit is active (off hook) when lit.

6. Timer / Timer Duration POT - 

The ADP

1

can be configured to

automatically disconnect a call after a preset amount of time has
elapsed.The timer can be set between 

1

5 seconds and 2 minutes.The

timer is activated by pressing the button on the unit or when the unit answers (Auto
Answer) an incoming call.With the timer disabled, the call time will be unlimited and
the ADP

1

will not disconnect the call until a 300 ms or longer loss of loop current

is detected. If the telephone line/phone system extension does not supply a loop cur-
rent break when the calling party hangs up, then the call timer feature must be used
(enabled). Clockwise rotation of the POT increases the duration.

7. Auto Answer - 

The ADP

1

can be configured to automatically

answer an incoming call.This feature can be enabled or disabled using
a jumper located on the PC board.

4

Settings

NOISE

REDUCTION OFF

4

5

7

ADP

1

PC Board

Содержание ADP1

Страница 1: ...Analog Door Phone Model ADP1 Installation and Use Manual 2004 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2098 01B 0607 ...

Страница 2: ...ctory authorized repair facility 6 DO NOT install telephone wiring during a lightning storm 7 DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations 8 Never touch uninsulated wires or terminals unless the line has been disconnected at the paging or controller interface 9 Use caution when installing or modifying paging or control lines Service Re...

Страница 3: ...els as well as a selectable Auto Answer feature to allow for remote monitoring The ADP1 also includes an adjustable and defeatable call timer and can respond to forward disconnect signals The ADP1 features a heavy gauge stainless steel gasketed faceplate plastic cone speaker and faceplate to electrical box user supplied gasketing to protect against vandals and varying weather conditions A dress be...

Страница 4: ...n only background noise not active audio is detected 5 Active LED For use when installing and troubleshooting the LED indicates that the unit is active off hook when lit 6 Timer Timer Duration POT The ADP1 can be configured to automatically disconnect a call after a preset amount of time has elapsed The timer can be set between 15 seconds and 2 minutes The timer is activated by pressing the button...

Страница 5: ...operation using the RJ11 or directly to the screw terminals depending on how the lines are terminated The connections to the terminal block are not polarity sensitive Surge Protection To increase surge protection connect a protective Earth Ground to the spare lug provided A ring lug is provided to which the protective ground lead is crimped Reassemble the lug to post as shown ...

Страница 6: ...aps between the box and the rough opening 3 Attach the self adhesive gasket to the back side of the bezel 4 Make electrical connections and attach the faceplate to the electrical box while capturing the bezel between the two using the four hex drive screws tool provided The faceplate fits into the depression in the bezel Surface Mounting the ADP1 Indoor Outdoor 1 Mount electrical box 2 Make electr...

Страница 7: ...tion 15 seconds to 2 minutes Loop Current Loss Disconnect 300 ms minimum Ring Voltage 40V AC RMS minimum REN 0 7A Connections 2 position pluggable terminal block Earth Ground lug Dimensions 5 W x 5 H x 21 4 D fully assembled 45 8 W x 45 8 H x 2 D aluminum box Product Weight 4 lb ...

Страница 8: ...ITNESS FOR A PARTICULAR PURPOSE ARE HERE BY DISCLAIMED AND EXCLUDEDTOTHE MAXIMUM EXTENT ALLOW ABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or oth erwise shall be limited to the price of the product In no event shall Bogen be liable for special incidental or consequential damages incl...

Отзывы: