Installation
Specification V250
Dimensions: Height 380mm Depth 260mm Width 260mm
Weight: 10kg (22lbs)
Voltage: 115-230V
Frequency: 50/60Hz
Full load current: 230V:1A 115V: 1.2A
Power: 140w
Capacity: 180m³h (106CFM)
Connection to Power Supply
Please follow the above specification when selecting the
power supply outlet for the extraction system, ensure the
power supply is suitable before connecting the V250
system.
Check the Integrity of the electrical power cable, if the
supply cord is damaged the extraction unit should not be
connected to the mains. The supply cord should only be
replaced by a BOFA engineer as an electrical safety test may
be required after replacement.
The extraction unit
MUST
be connected to a
properly earthed outlet.
If your extraction system was ordered with any
optional extras please read section
4.03
before
the power connection is made as additional connections
may be required before power is connected to the
extractor.
Connect the power cable to an isolated electrical supply.
The mains socket should be installed near the extractor it
should be easily accessible and able to be switched On/ Off.
The cable run should be arranged so as not to create a trip
hazard.