Installation 

 

 

 
Specification V250  
 

Dimensions: Height 380mm Depth 260mm Width 260mm 
Weight: 10kg   (22lbs) 
Voltage: 115-230V 
Frequency: 50/60Hz 
Full load current:      230V:1A              115V:  1.2A 
Power: 140w 
Capacity: 180m³h   (106CFM) 
 

Connection to Power Supply 

Please follow the above specification when selecting the 
power supply outlet for the extraction system, ensure the 
power supply is suitable before connecting the V250 
system. 
 
Check the Integrity of the electrical power cable, if the 
supply cord is damaged the extraction unit should not be 
connected to the mains. The supply cord should only be 
replaced by a BOFA engineer as an electrical safety test may 
be required after replacement. 
 

The extraction unit 

MUST

 be connected to a 

properly earthed outlet. 

 
 

If your extraction system was ordered with any 
optional extras please read section 

4.03

 

before 

the power connection is made as additional connections 
may be required before power is connected to the 
extractor. 

 
Connect the power cable to an isolated electrical supply. 
 
The mains socket should be installed near the extractor it 
should be easily accessible and able to be switched On/ Off. 
The cable run should be arranged so as not to create a trip 
hazard.  
 
 

 

 

 

 

 

 

 

 

01 

Содержание V250

Страница 1: ...V250 V1 Feb 15 ...

Страница 2: ......

Страница 3: ...Overview 01 Company Branding Filter Condition Light Lid Clips Air Inlets ...

Страница 4: ...Overview 02 Main Isolation Switch Mains Inlet Fuse Compartment Air Outlet Motor Cooling ...

Страница 5: ...ower supply before removing the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filter within the V250 system may contain a mixture of particulates some of which may be sub micron size When the used filters are moved it may agitate some of this particulate which could get into the bre...

Страница 6: ... markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning In the very rare event that a burning ember or spark is drawn into the fume extraction unit it may be possible that the filters will ignite Whilst any resultant fire would typically be retained within the fume extraction uni...

Страница 7: ...packaging This unit should be installed in a well ventilated area Ensure that 500 mm space is available around any vented panels on the extractor to ensure adequate airflow 2 Check the filter is located in its correct position before replacing the lid and securing the clips Caution Do not block or cover the airflow and motor cooling ports on the unit as this severely restricts airflow and may caus...

Страница 8: ...raction unit should not be connected to the mains The supply cord should only be replaced by a BOFA engineer as an electrical safety test may be required after replacement The extraction unit MUST be connected to a properly earthed outlet If your extraction system was ordered with any optional extras please read section 4 03 before the power connection is made as additional connections may be requ...

Страница 9: ... range at the ordering stage This allows the user to manually set the airflow from the V250 system Over time as the filters get blocked it is advised that the motor speed be increased to ensure the unit maintains good airflow To increase the airflow press and hold the up arrow The number of glowing blue LEDs will increase as the motor speed is increased To decrease the airflow press and hold the d...

Страница 10: ...ilters require attention when the display shows the configuration shown on the next page or when the extractor no longer removes fume efficiently All filters are tested to BS3928 A certificate of conformity for each filter is available on request It is recommended that a spare set of filters are kept on site to avoid prolonged unit unavailability Part numbers for replacement filters can be found o...

Страница 11: ...he unit Once removed it is recommend that the used filters are bagged and sealed 4 Lower the new filter into position Replace the lid and fasten the clips To remove and replace the pre filter follow the procedure detailed below 1 Isolate the electrical supply to the extractor 2 Undo the clips on the sides of the unit and remove the lid 3 Lift the pre filter out of the combined filter Once removed ...

Страница 12: ...ilter Date Engineer Date Engineer Filter disposal The combined filter is manufactured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance Deposit EWC Listing Comment Non Hazardous 15 02 03 Can be disposed of as non hazardous waste Hazardous 15 02 02M The ty...

Страница 13: ...ing speed Size Metric mm Imperial inches Height 420 16 7 Depth 260 10 2 Width 260 10 2 Filter Type Carbon Type Amount Carbon filter combined filter Activated Carbon Filters Filter Type Construction Efficiency Pre Filter Pad F7 96 2 microns Combined Filter Maxi Pleat Construction with Webbing Spacers 99 997 0 3 microns Environmental operating range Temperature 5o C to 40o C Humidity Max 80 RH up to...

Страница 14: ...Information BOFA Headquarters 21 22 Balena Close Creekmoor industrial Estate Poole Dorset BH17 7DX UK Phone 44 0 1202 699444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 001 618 205 5007 ...

Отзывы: