Feb.%2.%2012%
!
HOW!TO!COMPLETE!AN!INCLINE!CALIBRATION!
2012314!TREADMILLS!
Model!#!F9621****!
!
!
WARNING –
Do not stand on the belt during this procedure. If the incline calibration is
interrupted, do not use the treadmill. It is important to fully complete the incline calibration
procedure again before using the treadmill.
2012 T260P, T280P, T460XC, T520P, T560X
1. Enter the Diagnostics menu by pressing and holding the iTek button for 3 seconds.
2. You have correctly accessed the Diagnostics menu when you see DIAGNOSTICS on
screen and a scrolling message: “TXXX VERSION”.
3. Use the SPEED INCREASE & DECREASE keys to scroll through the Diagnostics menu
until ELEVATION CALBRATION is on screen.
4. Press the Just Go key twice to begin the Elevation Calibration
5. Once you see “COMPLETE” on the display, press the “Stop” key 4 times to return to the
“Welcome Screen”. Your treadmill is ready to go.
2012 T240S, T240S0, T260P, T280S, T280PO, T460XC, T520P, T560X
1. Remove the motor cover.
2. Locate the Incline Calibration button labeled “INCLINE”. It is
directly below the EPROM and above the LED Display on the
left side of the board. (See picture to right.)
3. Press and hold the button down for 3 seconds. The platform
will start elevating. As soon as the platform begins elevating,
release the button and the calibration will perform on its own (it
will last about 1 minute).
4. When the calibration is completed, start the unit and test the
speed and incline function correctly.
1. Reinstall the motor cover onto the treadmill.