background image

7

 

During 1 hour without reception of the time signal the clock operates with its own time basis. If 

the signal recovery is achieved within this hour, the clock will be resynchronised automatically. 

After 1 hour the clock is reset and hands are set on position 12.00.

 

Without power supply 230V the clock operates with its battery during 1 hour. After 1 hour 

without time signal reception or if the battery voltage drops down, hands are set position 12.00 

until power supply recovery.

 

The synchronous second hand witch is powered  by the main 12V 50Hz, will stop immediately. 

3.2.3. Radio receiver clock 

 

■ Switch off the circuit breaker involved.

 

Connect the mains 230 V +/-10% 50 Hz to the 

terminal (6) (Live, Neutral and Earth wires; section 

1.5 mm² to 2.5 mm² and bare on 5 mm). The mains 

cable must be oversheathed up to the terminal.

 

Attach the 3 wires (Live, Neutral an Earth) with the 

cable tie.

 

A double/reinforced electrical insulation must be 

assured between the mains cable and the SELV 

wires.

 

Connect the two wires of the antenna to the 

terminals 4 and 5 of the electronic card.

 

Check that the dip switch (16) is in receiver position.

 

Check that the battery is connected to the terminal (2) of the electronic card.

 

Lock the clock.

 

Push the dip switch (15) to the ON position.

 

Close the clock.

 

Power the clock.

Operating principle of radio receiver clock

 

When switching on power supply, hands are set 

at 12.00 until the correct reception of the time 

signal is achieved. After 3 successive coherent time signals are received, the clock starts and 

automatically get on time with fast impulses.

 

Once the clock is synchronised, it operates with its own time basis. If the signal is back within 

this period, the clock set itself automatically.

 

Without power supply 230V the clock operates with its battery during 1 hour. After 1 hour 

without time signal reception or if the battery voltage drops down, hands are set position 12.00 

until power supply recovery.

 

The synchronous second hand witch is powered  by the main 12V 50Hz, will stop immediately. 

5

6

4

3

3

1

15

16

AF

FI

Input 162

Содержание Profil TGV 950

Страница 1: ...er INSTALLATION AND OPERATING INSTRUCTIONS 1 rue du G n ral de Gaulle 49340 TR MENTINES FRANCE T l 02 41 71 72 33 www bodet time com Upon receipt always check the product for damage during shipment If...

Страница 2: ...g 3 II DISCLAIMER 4 III INSTALLATION 4 3 1 Mechanical installation 4 3 2 Setting in operation 5 3 2 1 AFNOR IRIG B receiver clock 5 3 2 3 Radio receiver clock 6 3 3 Setting the antenna 7 IV SAFETY INS...

Страница 3: ...3...

Страница 4: ...nvalidate the warrantee 1 1 Unpacking the clock Unpack with caution and check the contents of the packaging It must contain the TGV clock for radio synchronised models the antenna a key to open the ca...

Страница 5: ...hapter Safety instructions in this manual before installing this equipment III INSTALLATION 3 1 Mechanical installation Select the place where the clock will be installed while making sure that radio...

Страница 6: ...5 mm The mains cable must be oversheathed up to the terminal Attach the 3 wires Live Neutral an Earth with the cable tie A double reinforced electrical insulation must be assured between the mains ca...

Страница 7: ...t be assured between the mains cable and the SELV wires Connect the two wires of the antenna to the terminals 4 and 5 of the electronic card Check that the dip switch 16 is in receiver position Check...

Страница 8: ...o system a building with metal structures can cause interference in the reception of the signal Computers television sets and electrical appliances can also cause interference that disrupt the recepti...

Страница 9: ...le see section Installation Caution use of an unqualified battery may present a risk of explosion Waste battery should be disposed so that they can be recycled LED lights can be hazardous to the eyes...

Страница 10: ...umption 14 W Dimensions TGV 970 Readability 50m Weight 16 kg Lighting consumption 20 W Dimensions 322 162 500 140 230 270 24 trous 8 20 Double face clock Single face clock Disk for hanging bracket or...

Страница 11: ...nel The battery must be model VARTA Ni MH 5 CP300H 6V 280mAh Accuracy absolute with automatic summer winter changeover AFNOR IRIG B receiver clock with synchronous second hand Permanent power supply 2...

Страница 12: ...clock min min AFNOR Irig B is in accordance with the type programmed in the clock AFNOR Irig B receiver stopped at 12h00 Lack of impulse since more than 1 hour check the master clock and the network...