15
- Reboot:
This setting is used to detect a clock reboot.
- Scheduled melody:
This parameter triggers an alarm when a programmed melody is played.
- Manual melody:
This parameter is used to trigger an alarm when melody is initiated manually.
- Streaming:
the device sends back the information that an audio stream is in process of being
played.
- Alert melody:
This parameter triggers an alarm when an alert melody is broadcast.
- Missing File:
this parameter sets off an alarm if a text is alone without an associated melody or
flash .
- Web access:
This setting is used to trigger an alert if a user connects to the web server of the
clock.
- Authentication failure:
This setting is used to trigger an alert if a user sends an incorrect ID to
the web server of the clock.
- Synchronisation failure
: This setting is used to detect synchronisation discrepancies with the
master clock (type Sigma) or the time server (type Netsilon).
Multicast: Alarm triggered when the multicast synchronisation is absent for at
least 1hour
Unicast: Alarm triggered when the unicast synchronisation is absent for 3 times
the duration of the poll (periodicity) and at least 1 hour (allowing for the NTP
server maintenance)
- Repeater failure:
This parameter triggers an alarm when a fault occurs on the repeater.
- Periodic Status:
This setting is used to verify that the device is still working correctly. This verifi
-
cation is carried out at a set frequency.
- SNMP test:
The button
is used to send a trap status to all of the configured SNMP
managers to ensure that supervision is configured correctly.