7) CONFIGURATION

To access this menu, press the “SELECT” key, hold it down and press the “+” key 

for 3 seconds. 

Caution: the seconds are reset to zero automatically when you enter the configuration 

menu. 

 

a - Operating mode

The clock displays (in accordance with the model) the last operating mode selected:

Operating 

mode 

   Display

Independent 

   

Minute Receiver   

 

Half-Minute Receiver 

 

 

Calibration    
Coded Time Receiver 

 

 

World Clock 

 

 

Select the required operating mode using the “+” key.

Remark: check that the selected mode corresponds both to the required use (for 

example, minute receiver) and to the clock’s information label (for example, “Ind.- 

Impuls.”).
When the selected mode, for example “Ind”, appears on the display, press the 

“Select” key to validate it. Do not validate Calibration mode, which is reserved for the 

manufacturer.
In “World Clock” mode, it calculates and displays the local time using the coded time 

information received and its summer/winter time change (paragraph c) and time 

difference (paragraph d) parameters. 

Remark: you can exit from this menu at any time. Simply press the “Select” key, hold 

it down and press the “+” key. Then release both keys. 

Содержание Style 5S

Страница 1: ...ation and operating instructions BP30001 49340 TRÉMENTINES FRANCE Tél 02 41 71 72 00 Fax 02 41 71 72 01 www bodet time com Réf 606726 G When receiving goods please chek nothing is broken otherwise make a claim near shipping company ...

Страница 2: ...2 MECHANICAL INSTALLATION 4 3 ELECTRICAL INSTALLATION 5 4 POSITION OF SELECT AND KEYS 5 5 ADJUSTING THE BRIGHTNESS 6 6 TIMER FUNCTIONING 6 7 CONFIGURATION 7 8 TIME SETTING 9 9 MEMORY BACKUP 11 10 TECHNICAL CHARACTERISTICS 11 11 CLEANING 11 ...

Страница 3: ...e 5 Style 7 etc the operating voltage the type of clock and various other items of information Check that the Style clock supplied to you corresponds to the planned use REC AFNOR The clock must be integrated in a coded time distribution network complying with the AFNOR standard or IRIG B extended DIEM IND M 1 2M The clock can be configured in independent mode or integrated in a time distribution n...

Страница 4: ...4 2 MECHANICAL INSTALLATION Install the clock and its control panel in their positions The watertightness is accomplished at installation time by a silicon gasket between the front panel and the wall ...

Страница 5: ...olt 50 60 Hz mains power supply do not switch on before the control panel and the time distribution are connected Setting of the clock to the correct time is automatic in AFNOR mode and manual in the autonomous or 24 V minute impulse version see section 7 page 6 Programming and brightness adjustment are carried out with the two programming keys SELECT and 4 POSITION OF SELECT AND KEYS These two ke...

Страница 6: ... to be managed whatever the operating mode independent or receiver The timer can function in count up mode Controls available TIME key 5 with LED used to select the time display This key is taken into account even when the timer is in operation without stopping the timer TIMER key 7 with LED used to select the operating mode of the timer count up from 0 00 00 to 23 00 00 START STOP key 3 starts an...

Страница 7: ...ey Remark check that the selected mode corresponds both to the required use for example minute receiver and to the clock s information label for example Ind Impuls When the selected mode for example Ind appears on the display press the Select key to validate it Do not validate Calibration mode which is reserved for the manufacturer In World Clock mode it calculates and displays the local time usin...

Страница 8: ...esponds to alternate display of the time and the week number Validate by pressing the Select key You will then exit from the configuration menu c Selecting the summer winter time change Summer winter time changes can be made automatically only on independent or radio synchronised clocks In the case of a minute or half minute receiver clock this selection is not active the Style clock will always c...

Страница 9: ...e impulse version The button on the control panel must be set to the time position a With the normal display on the readout or with Bat displayed following a prolonged mains failure press the Select key The clock displays the time and the minutes flash Press the key to increment the minutes when you hold the key down the minutes advance rapidly Every time the key is pressed the seconds are reset t...

Страница 10: ...23 59 or 12 AM display for English speaking countries from 1 00 to 12 59 Use the key to choose between these two options Validate by pressing the Select key d The year flashes Select the current year from 1993 to 2092 using the key and then validate by pressing the Select key e The month flashes Select the current month using the key and then validate by pressing the Select key f The day of the mo...

Страница 11: ...gnetic compatibility directive 89 336 EEC They are designed for a residential commercial or industrial environment They comply with the following European standards NF EN 55022 December 1994 radio interference produced by information processing devices NF EN 50082 1 June 1992 generic standard for immunity electromagnetic compatibility Style clocks comply with Low Voltage Directive 73 23 EEC by ref...

Страница 12: ...12 ...